Ambient conditions
Ambient temperature
Device performance data
Tank content
Air quantity
Air flow volume during opera-
tion
Vacuum
Operating pressure
Nominal width of the suction
hose
Determined values in acc. with EN 60335-2-69
Hand-arm vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Mains cable
Mains cable H07BQ-F
Part number (EU)
Cable length
Subject to technical modifications.
Declaration of Conformity
EU Declaration of Conformity
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements in the
EU Directives, both in its basic design and
construction as well as in the version
placed in circulation by us. This declaration
is invalidated by any changes made to the
machine that are not approved by us.
Product: Dry vacuum cleaner
Product: Wet/dry vacuum cleaner
Type: 9.986-xxx
Type: 9.989-xxx
IVR
40/15
Sc
°C
+40
l
40
l/s
58
l/s
37.5
kPa
20
(mbar)
(200)
kPa
16
(mbar)
(160)
DN50 DN50 DN50 DN50 DN50 DN50 DN50
2
m/s
< 2.5
2
m/s
0.2
dB(A) 57
pA
dB(A) 2
2
mm
4 x 2.
5
9.979-
856.0
m
7.5
English
IVR
IVR
IVR
40/30
50/15
50/30
Sc
Sc
Sc
+40
+40
+40
40
50
50
87.5
58
87.5
56.5
37.5
56.5
26
20
26
(260)
(200)
(260)
21
16
21
(210)
(160)
(210)
< 2.5
< 2.5
< 2.5
0.2
0.2
0.2
62
57
62
2
2
2
4 x 2.
4 x 2.
4 x 2.
5
5
5
9.979-
9.979-
9.979-
856.0
856.0
856.0
7.5
7.5
7.5
Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
2014/30/EU
2011/65/EU
Harmonised standards used
EN 55014-2: 2015
EN 55014-1: 2017 + A11: 2020
EN 60335-1
EN 60335-2-69
EN IEC 61000-3-2: 2019
EN 61000-3-3: 2013 + A1: 2019
EN 61000-3-11: 2000
EN 62233: 2008
EN IEC 63000: 2018
The signatories act on behalf of and with
the authority of the Executive Board.
IVR
IVR
IVR
50/40
100/
100/
Sc
30 Sc
40 Sc
+40
+40
+40
50
100
100
137.5 87.5
137.5
88.5
56.5
88.5
14
26
14
(140)
(260)
(140)
11.5
21
11.5
(115)
(210)
(115)
< 2.5
< 2.5
< 2.5
0.2
0.2
0.2
71
62
71
2
2
2
4 x 2.
4 x 2.
4 x 2.
5
5
5
9.981-
9.979-
9.981-
557.0
856.0
557.0
7.5
7.5
7.5
19