Descargar Imprimir esta página

Royal Catering RCSI-18A Manual De Instrucciones página 37

Máquina de helado suave

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 117
Troubleshooting
Problems
The machine is not
working
The machine does not
work in cleaning mode
The machine does not
work in automatic mode
The compressor is not
working
The machine does not
freeze
The machine freezes all
the time
The relay is not stable
The product does not
have a dispenser
Product too soft
EN
Possible cause
The machine is not connected to the
wall socket
The power switch is open
The connecting cable is disconnected
The rammer motor has broken down
The mini circuit breaker was
damaged.
The function switch wire is
unplugged
There is a problem with the control
panel
Low voltage
The contactor is broken
The compressor relay has broken
There is a problem with the control
panel.
Compressor self-protection against
overload.
The compressor is broken
The compressor capacitor has
broken
Refrigerant leakage
The electric valve is broken
Fan motor not working
The fan motor capacitor has broken
The setpoint is too low
There is a problem with the control
panel.
Refrigeration difference
Low voltage
There is a problem with the control
panel.
The touch point of the contact
switch is broken.
The mixture ratio is incorrect and
causes a difference in cooling
No mixture in the tank
The limit switch is damaged or the
cable is loose.
The belt is loose or slipping
Worn bearing bush or tamper shaft
The proportions in the formula are
incorrect
The setpoint is too low
Remedy
Connect the machine
Restart it after repositioning
Check and fasten the wire.
Repair or replace the beater motor
Find and fix the problem, then
reposition it
Check and fasten the wire.
Change the control panel.
Solve the problem of low voltage
Change contactor
Change the control panel.
Change the control panel.
Find and solve the problem
Change compressor
Change the capacitor
Find and repair the leak in the pipe,
then vacuum and add refrigerant
Change the electric valve
Repair or replace fan motor
Change the fan motor capacitor
Increase the setting
Change the control panel
Check and repair the refrigeration
system
Solve the problem of low voltage
Change the control panel.
Remove the touch point or change
the contact switch.
Prepare the appropriate
proportion of the mixture.
Pour the mixture into the hopper
Change the switch or attach the
cord
Change or adjust the belt
Replace the bearing bush or
tamper shaft.
Mix the mixture according to the
recipe provided by the supplier.
Increase the setting

Publicidad

loading