Troubleshooting
If you encounter problems with your device, refer to the table below for a solution. If the
problem persists, do not solve it yourself and contact the manufacturer's technical service
for assistance.
Problem
The machine is not
working
Cleaning mode does not
work
Automatic mode does
not work
The compressor does not
work
The machine does not
freeze
The machine does not
stop
The relay is turned off
Ice cream does not flow
from the dispenser
EN
Probable causes
The machine is not connected. Check and connect correctly.
The main switch is not turned
on.
The main switch is damaged.
The protection circuit is
operational.
The wiring for this function is
loose.
The drive motor does not
work.
The wiring for this function is
loose.
The control board is not active
The tension is low.
The relay is bad.
There is something wrong
with the control board.
Overload protection works.
The compressor is damaged.
The compressor capacitor is
not working.
Refrigerant leakage.
The solenoid valve does not
work.
Fan motor not working.
The compressor is not
working.
The hardness is set too high.
There is something wrong
with the control board.
Bad cooling system.
The tension is low.
There is something wrong
with the control board.
The contactor is burnt.
Improper mixture caused the
cylinder to freeze.
No mixture in the cylinder.
The limit switch does not work
or the limit switch wiring is
loose.
Solutions
Turn on the master switch.
Replace the main switch with a new
one.
Change the fuse.
Check the cabling and connect it.
Repair or replace the engine.
Check the cabling and connect it.
Replace the control board.
Try to get high and stable voltage.
Replace the control board.
Replace the control board.
Find the cause and restart.
Replace the compressor.
Replace the capacitor.
Find the leak location and repair it, refill
the refrigerant after vacuuming the
refrigeration system.
Replace the solenoid valve.
Repair or replace the fan motor.
Check the compressor and replace it if
necessary.
Reduce the hardness setting.
Replace the control board.
Check the refrigeration system.
Try to get high and stable voltage.
Replace the control board.
Replace contactor.
Prepare the appropriate mixture.
Add the mixture to the hopper.
Replace limit switch or change wiring.