_______________________________________________________________
6
Faults and
malfunctions

6.1 Safety instructions

The following information always applies for resolving
problems:
Danger due to voltage!
Contact with voltage can
cause severe injury or
death by electric shock!
Attach or detach connectors only
when the equipment is de-
energised.
Do not open the housings of the
following components:
- Controller
- Columns
- Operating panel
Table of error messages
Error message
Name
Unexpected Reset
8
LIN error
9
Power fail
10
Channel count changed
11
Position difference
12
Short circuit
13
Checksum
14
Power limit
15
Key error
16
No Safety
17
Missing initialisation plug
18
Channel 1 missing
23
Channel 2 missing
24
Channel 3 missing
25
Channel 4 missing
26
Channel 5 missing
27
Channel 6 missing
28
20

Faults and malfunctions

ATTENTION
Risk of damage to electrical equipment!
Do not use the mains cable to pull
the plug out of the socket.
Error messages on the display of the Active
Touch operating panel
If faults occur during operation of the Ology desk,
please check whether it is operated in accordance
with the user manual. In most cases, this manual will
help you to locate and correct the fault.
Some errors that may occur are shown on the display
of the Active Touch operating panel. The "Error"
segment flashes.
The table below should help you to find the cause
and to correct the error or fault.
Description
Unexpected error message due to external reset
Fault in "LIN bus" (local connection network)
Power failure or voltage regulator set below 10%.
Number of channels connected to the system has changed
Difference between minimum and maximum position ex-
ceeded
Short circuit detected during operation
Item checksum failed
System has reached voltage limit
Invalid key combination / Change of keys
Safety system prevents movement
Special tool necessary to change the number of connections
Drive element not detected
120917