3. Disconnect the cables from the broken lamp.
4. Push the broken lamp toward the inner lamp
attachment (B).
5. Lift the outer edge (C) of the lamp to remove the
lamp.
6. Replace the broken lamp. Use the type of lamp as
given in
Technical data on page 44 .
7. Connect the cables to the new lamp.
8. Connect the cables at the connection (A).
A
9. Attach the cover and tighten the 2 screws.

To do a check of the parking brake

1. Park the product on a hard surface that slopes.
26
B
Note: Do not park the product on a grass slope when
you do a check of the parking brake.
2. Press the parking brake pedal down (A).
3. Press and hold the lock button (B) and release the
parking brake pedal while the button is pressed.
4. If the product starts to move, let an approved service
agent adjust the parking brake.
5. Press the parking brake pedal again to release the
parking brake.

To replace the fuel filter

1. Remove the engine cover to get access to the fuel
filter. The right illustration shows P 524. The left
illustration shows P 524EFI.
C
2. Move the hose clips away from the fuel filter with a
pair of flat pliers.
3. Pull off the fuel filter from the hose ends.
4. Press the new fuel filter into the ends of the hoses.
Apply liquid detergent to the ends of the fuel filter to
make the connection easier.
5. Push the hose clips against the fuel filter.

To clean and replace the air filter

CAUTION: Do not start the engine when the
air filter is not attached.
1. Remove the engine cover.