Starting Basic Operation; Operating Mode - Astralpool PROHEAT II Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
Maximum evaporation
F82
temperature (MOP
F83
M.O.P.
F84
Time M.O.P.
Visualización tiempo en marcha
F85
acumulado
F86
Probation time
System
settings
Reset tiempo en marcha
F87
acumulado
F88
Reset factory parameters
F90
Show the card model
F91
Show the card software version
F92
Show the model of the display
Display the main board software
F93
version number
Test
F96
Time setting
F97
Reserved for the manufacturer
F98
Reserved for the manufacturer
F99
Test output signals
F00
Exit
* Observation1:When F24=1, this means there is only one circuit. Therefore, none of the
System 2 inputs/outputs can be used. And no error codes will be displayed. Also, the error codes
A13, A14, A23, A25, A27 will not be shown.
6.4.

6.4.1. OPERATING MODE

The regulator has 4 operating modes, depending on the heat pump model: Cool, Heat,
Auto and Manual selection of the operating mode. The available operating mode is controlled
by parameter F29.
F29=0, only Auto mode (C/H).
F29=1, only Heat mode (C/H).
F29=2, only Cool mode (C/H).
F29=3, Manual selection of the operating mode (M).
In the Cool mode, the machine starts cooling when the probe temperature is higher than
the "Temperature setpoint + Temperature differential" and it stops cooling when the
temperature is lower than the "Setpoint temperature - Differential temperature".
In the Heat mode, the machine starts heating the water when the probe temperature is
lower than the "Temperature setpoint + Temperature differential" and it stops heating when
the temperature is higher than the "Setpoint temperature - Differential temperature".
In the Auto mode, the machine starts cooling when the probe temperature is higher than the
"Temperature setpoint + Auto mode temperature differential" and it stops cooling when the
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
10 – 100
1 – 5
1 – 3
0 -- 999
no/yes
no/yes
This function is only for tests. It is forbidden to use it online. Press "S" to exit.
Press "S" to exit.
After entering this function, it shows the "AdF".
After entering this function, it will show "CCC". The relays will be activated one by
one. This function is only for tests. It is forbidden to use it online. Press "S" to exit.

STARTING BASIC OPERATION

ENGLISH
Maximum evaporation temperature
20
ºC
(MOP)
High evaporation temperature
2
ºC
protection
Time of High evaporation
2
min
temperature protection
-
Day
The controller will stop if the
accumulative time is over probation
OFF
Hour
time, and show the alarm code
"A99".OFF means no probation time
no
-
Reset of all parameters. Reset if the
no
-
card software is updated.
Pag: 24