User Calibration - Hofmann geodyna 7850p Manual De Operador

Ocultar thumbs Ver también para geodyna 7850p:
Tabla de contenido

Publicidad

W
126
6-2
2
6-4
6-5
Power Clamp
6-6
Maintenance

6.2 User Calibration

If several measuring runs are necessary to balance
a wheel because balance weight size and position
have to be adjusted repeatedly, this is often due to
insuffi cient measurement accuracy.
If this is the case the operator can electronically
calibrate the rotating masses on the machine; which
is called User Calibration.
A calibration run takes longer than a regular measuring
run.
Following User Calibration any residual compensation
will be cancelled.
Important:
User Calibration should only be performed with
nothing on the shaft; and with no external tools
whatsoever on the wheel holder.
THE CLAMPING TOOL SUPPLIED WITH THE
MACHINE SHOULD BE LOCKED ON THE SHAFT.
Readjustment
— Make sure that no clamping tool other than the one
supplied (and no wheel or other device) is mounted
on the machine shaft.
— From the MAIN MENU (Fig. 6-1) press the 3 key
three times and select the C 14 CALIBRATION
(Fig. 6-4).
The CALIBRATION 1 screen (Figure 6-5) page will open.
— Close the wheel guard, press the START key and
launch the fi rst calibration run (if the run takes a
long time it means residual imbalances have been
detected).
The CALIBRATION screen 2 will open.
— Screw the Calibration weight onto the threaded hole
in the wheel support fl ange W (Figure 6-6).
— Press the START key and launch a second
calibration run (to detect correction values).
After the second run the electronic control unit
processes the values taken during the calibration runs
and writes them in the permanent memory. When
this has fi nished an audible 3-tone signal is heard to
indicate that User Calibration has terminated.
— Unscrew the Calibration weight from the fl ange W
and put it back in its designated place in the Weight
Holder Tray.
— Press the ESC key to return to the INTRODUCTION.

Publicidad

Tabla de contenido
loading

Tabla de contenido