Setting Parameters
Saving Changed Parameters
Changes to operating modes can be saved permanently
using the "Saving operating modes in the permanent
memory" function so they are retained every time the
machine is started up.
Operating modes that are changed but not saved are
reset to the pre-change value after the machine has
been switched off.
Saving modes of operation in permanent
memory
NO*
= No storage
Active = Fixes the data in the permanent memory
Store in the permanent memory – a three–tone signal
is given to acknowledge acceptance.
If the mode stored in the permanent memory is to be
changed, enter the desired state (e. g. on or off) for
the mode in question and transfer it into the permanent
memory.
7.4.1
Settings List
Selection of some functions (On / Off) and threshold
settings by the operator directly affect the Run-out
and the advanced functions that the machine might
display on screen.
From the Optima Mode, customised options can be
set for the following parameters.
SETTINGS: (Fig. 7-5)
A) Selection of Operating Mode for the current session.
Default setting: Optima Full Diagnostic.
B) Limit (threshold) for wheel radial Run-out of 1
Harmonic. Default value: 0.7 mm.
C) Set rim run-out measurement (if set to "Limit
exceeded," measurement is taken only if limit is
exceeded; if set to "Always," measurement is always
taken). Default value: Always.
Factory adjusted mode
* =
st