Specifications

Model ..........................................................K9-102
Drain Capacity (Nom.) ................................1
Cable Diameter (without Sheath)................
Cable Assy. Diameter (with Sheath) ...........
Cable Assembly Length ..............................50' (15.2 m)
Rotational Speed ........................................Maximum 2500 RPM
Drill Attachment ..........................................
Weight (without Drill/Knocker) .................. 24.3 lbs. (11.0 kg)
Dimension (without Drill) ...........................19.2" × 7.5" × 22.1"
Operating temperature................................20°F to 140°F (-6°C to 60°C)
It is not recommended to clean glass, ceramic,
porcelain or similar fixtures with the FlexShaft
Drain Cleaners as it may damage the fixture.
Specifications - Acceptable
Battery Powered Drills
Rotational Speed .... 1800 to 2500 RPM
Chuck Size ............. 3/8" or greater
Clutch ..................... With adjustable torque
Switch Type............. Momentary Contact
Switch Lock ............ Not equipped with
Drill must carry appropriate certification mark
for the market (CE mark, c()us mark, etc.)
Do not use corded drills, hammer drills or
impact drivers. Use of an inappropriate drill
increases the risk of equipment damage and
personal injury. See Battery Powered Drill
Set-up and Operation section.

Standard Equipment

Refer to the RIDGID catalog for details on e-
quipment supplied with specific drain cleaning
machine catalog numbers.
This machine is made to clean
NOTICE
drains. If properly used it will not damage a
drain that is in good condition and properly
designed, constructed and maintained. If the
drain is in poor condition, or has not been
properly designed, constructed and main-
tained, the drain cleaning process may not be
effective or could cause damage to the drain.
The best way to determine the condition of
a drain before cleaning is through visual in-
spection with a camera. Improper use of this
drain cleaning machine can damage the drain
cleaning machine and the drain. This machine
may not clear all blockages.
999-995-158.09_REV. C
FlexShaft™ Drain Cleaning Machines
/
" to 2" (32 – 50 mm)
1
4
/
" (6 mm)
1
4
/
" (9.5 mm)
3
8
/
" Hex (8 mm)
5
16
(488 mm × 191 mm × 562 mm)

Pre-Operation Inspection

Before each use, inspect your Drain
Cleaning Machine and correct any prob-
lems to reduce the risk of serious injury
from electric shock, twisted or broken
cables, chemical burns, infections and
other causes and prevent Drain Cleaning
Machine damage.
Always wear safety glasses, and other
appropriate protective equipment when
inspecting your Drain Cleaning Machine.
1. Clean the machine, including handles
and controls. This aids inspection and
helps prevent the machine or control
from slipping from your grip. Clean and
maintain the machine per the mainte-
nance instructions.
2. Inspect the machine for:
• Proper assembly and completeness.
• Any broken, worn, missing, misaligned
or binding parts.
• Presence and readability of the warning
label (see Figure 2).
RIDGID.com
Figure 2 – Warning Label
K9-204
2" to 4" (50 – 100 mm)
/
" (8mm)
5
16
/
" (12.7 mm)
1
2
70' (21.3 m)
Maximum 2500 RPM
/
" Hex (8 mm)
5
16
37.3 lbs. (16.9 kg)
21.1" x 10.8" x 24.2"
(536 mm x 274 mm x 615 mm)
20°F to 140°F (-6°C to 60°C)
WARNING
1800-2500
/min
Max. 75%
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Flexshaft k9-204