Product Marking; Special Conditions For Safe Use "X; Type Of Protection Constructional Safety "C - Nederman FlexFilter EX Manual De Instrucciones

Ocultar thumbs Ver también para FlexFilter EX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
EN

Product marking

The FlexFilter EX is ATEX classified and marked:
II 3D Ex h IIIC T130ºC Dc
-10ºC≤Ta≤40ºC
Nederman 19.HB01X
Part
II:
h:
IIIC:
T130ºC
Dc:
-10ºC≤Ta≤40ºC
Nederman 19 .HB01X

Special Conditions for Safe Use "X"

The FlexFilter EX is designed to be a part of a complete extraction system . A complete extraction system usually
includes a vacuum unit, connected piping and a control system as described in this manual. For the FlexFilter EX
to function properly and fulfil necessary safety requirements as stated in the Declaration of Conformity, the com-
plete system must be assessed with regards to applicable safety standards and directives and comply with all
requirements described in this manual. The designer of the system as a whole, must guarantee correct function of
all interacting products or components and ensure that the complete system meets all necessary safety require-
ments .

Type of Protection constructional safety "c"

Technical documentation contains the information required to maintain the product safety .
20
FlexFilter EX
Explanation
Equipment group (non mining equipment) .
The letter "h" as specified in EN ISO 80079-36
Equipment of Group III is intended for use in places with an explosive dust atmos-
phere other than mines susceptible to firedamp.
Equipment of Group III is subdivided according to the nature of the explosive dust
atmosphere for which it is intended .
Group III subdivisions:
• IIIA: suitable for combustible flyings;
• IIIB: suitable for combustible flyings and non-conductive dust;
• IIIC: suitable for combustible flyings, non-conductive dust and conductive dust.
The maximum surface temperature in degrees Celsius .
Equipment protection level Dc . Same as old 3D marking .
For explosive atmospheres, caused by mixtures of air and combustible dusts, the
equipment does not contain any effective ignition sources in normal operation.
Ambient temperature range .
Certificate number. If the sign "X" is placed after the certificate number, it indicates
that the equipment is subject to specific conditions for safe use.

Publicidad

Tabla de contenido
loading

Tabla de contenido