5. COMMISSIONING

The guide only describes commissioning using a Situo io type Somfy io local control point. For
commissioning using any other io control point, refer to the corresponding guide.

5.1. Identifying setting steps already completed

Only one motor should be powered at a time.
Switch on the power and follow procedure "a" or "b",
according to the awning's reaction:
The awning moves briefly
a
The end limits are set and no Somfy io control point
has been programmed.
Go to the section"Programming the first Somfy io local
control point".
or
The awning does not move
b
Press the Up or Down button, and follow procedure "c"
or "d" according to the awning's reaction:
The awning still does not move
c
The end limits are not set and no Somfy io control
point has been programmed.
Go to the section "Pre-programming the Somfy io
local control point".
or
d
The awning is fully raised or lowered
The end limits are set and the Somfy io control point
has been programmed.
Go to the section "Operation".

5.2. Pre-programming the Somfy io local control point

-
Press the Up and Down buttons simultaneously: the
awning will move briefly; the Somfy io local control point
has been pre-programmed into the motor.

5.3. Checking the motor's direction of rotation

1)
Press the Up button:
a)
If the awning is raised, the direction of rotation is
correct: go to the section "Setting the end limits".
b)
If the awning is lowered, the direction of rotation is
incorrect: press the "my" button until the awning moves
briefly; the direction of rotation has been modified.
2)
Press the Up button to check the direction of rotation.
40
1
a
b
2
Copyright © 2010 Somfy SAS. All rights reserved.
ON
Programming the
1st Somfy io local
control point.
or
c
d
Pre-programming the
Somfy io local control
point.
Operation.
Setting the end
limits
2 s

Publicidad