Operation
5.17.3 Start optimisation or weight
minimisation
Procedure:
— Clamp the wheel or bare rim.
— Enter correct rim dimensions, or check existing
inputs for correctness.
— Close the wheel guard (if necessary press the
START key).
— Starting from the BALANCING Menu press key 6
Optimisation-Minimisation (Fig. 4-10).
The OPTIMISATION MENU screen "1" is displayed
(Fig. 5-65).
If an optimisation/minimisation result has already been
saved, press key 7 (Fig. 5-66); in this way, the program
continues from the step where it was interrupted, with
the relative measurement values and settings, and the
optimisation/minimisation may continue.
At this point, you can choose whether to continue with
Optimisation (Key 8), or go to Minimisation (Key 4).
5.17.3.1 OPTIMISATION
— Clamp the rim only.
— Move the gauge arm into position on the rim, based
on the desired ALU.
— Perform a measuring run.
— In the BALANCING Menu press key 3 (Fig. 5-33).
The "1" screen page appears (Fig. 5-66).
— Press the menu key 8 (Fig. 5-66).
The OPTIMISATION "2" screen appears (Fig. 5-67).

Publicidad

Tabla de contenido

Solución de problemas

loading