148
Trouble shooting
Press STOP or ESC key to check the switch.
If the error cannot be remedied, the pedal function is
switched off by pressing the STOP key or the ESC
key. Call service.
E92
Geodata gauge for distance and rim diameter is
defective.
— Call technical support.
— As long as the gauge is defective, enter distance
and rim dimensions by pressing the menu key and
rotating the wheel (
F
E93
The Geodata width gauge arm is defective.
— Call technical support.
— As long as the width gauge is defective, enter rim
width by pressing the function key and rotating the
wheel (
5.7.2).
F
E141
The content of the number 1 permanent memory is
not reliable. The balancing can only be performed in
certain conditions.
— Call technical support.
E144
The CRC of the EEPROM 1 and 2 are incorrect.
E145
The contents of both permanent memories are
different, but both contain valid data.
E341
The content of permanent memory number 2 is not
reliable. The balancing can only be performed in certain
conditions.
— Call technical support.
from E360 to E378
The sensors are not operating correctly.
— Switch the machine off and back on. If the problem
persists, call technical support.
E500
Laser Pointer failure
• Contact technical service team.
E501
Laser Pointer failure
• Contact technical service team.