AVENTICS | CD01-PI | R412012449–BAL–001–AD
Assembly
6.5.3

Connecting the bus coupler

The CD01-PI can only be used for fieldbus control in the 24 V DC
version.
Please observe the operating instructions of the respective bus
coupler.
A conversion kit R412012497 is required to convert a VS with
multipole plug box for fieldbus control. The conversion kit
contains:
one flat cable
two M5 screws
Proceed as follows:
1. Remove the plug box on the left end plate. To do this,
loosen both screws (46).
2. Release the flat cable multipole connection on the left end
plate by removing the socket screw (47) tugging the
multipole connection gently.
You have removed the plug box. You can now install
the flat cable for connecting a bus coupler on the left
end plate.
3. Insert the flat cable socket in the left end plate plug. Secure
the socket with screw ∅ 3x7 (47).
Tightening torque: 0.5 Nm
4. Then insert the flat cable plug for the bus coupler in the
opening at an offset of 90°. Now also secure the plug with
a screw ∅ 3x7 (48).
Tightening torque: 0.5 Nm
You can now connect the bus coupler on the valve system.