Nussbaum BM 11 Instrucciones De Uso página 59

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
The units can be changed by the use of key 4 or 5.
Press key ENTER key (12) again to activate the func-
tion and the program will automatically return to normal
mode.
Display in Grams
Display in Ounces
F4:
Factory Settings
This function will enable all original factory settings for
parameters on the machine to be retrieved. These are
arranged into two groups:
a.) Rounding off values, Measurement values or safety
settings.
b.) Calibration values for the main shaft assembly and
the gauges as well as the zero calibration value.
Routine:
Activate the function program using ENTER key (12) and
select the function F4 using +/- key (4/5), (6/7) or (8/9).
Press ENTER key (12) to activate the function.
Option 1
The program can be exited without any changes being
made by pressing the „STOP" key (11).
!
After activating the following procedures, the new
data will automatically be saved and all previous
saved data will be lost.
Option 2
Press the „Save – key" (16) and the display shows „Set
CAL".
The calibration data for the gauges, main shaft assem-
bly and zero calibration will then revert to the factory
settings as follows:
Distance A
Diameter d
Width
b
1 689 979 917N
03.07.2013
20
Tolerance
225
Tolerance
525
Tolerance
The zero calibration and the calibration data for the
main shaft assembly will revert to the standard values.
It is nevertheless important to carry out another zero run
and full calibration on the machine.
After the data has been changed, the program will re-
vert to standard calibration mode.
Option 3
Press ENTER key (12). The display will Show
The following settings will revert back to the factory set-
tings:
Safety settings
Automatic start function
Wheel data save function
Unit of weight measurement
Unit of measurement for gauges
Rounding off/ Suppression
Wheel data (A / d / b)
The data will change automatically and the program
will revert to the standard balance mode.
F5:
Calibration
If several measuring runs are necessary to balance a
wheel because balance weight size and position have
to be readjusted repeatedly, this i soften due to insuf ci-
ent measurement accuracy. In such cases the operator
has the possibility of readjusting the machine.
Readjustment can also be carried out after about 500
measurement runs (see F11).The calibration can only
be carried out with the supplied calibration weight and
clamping adaptor. The calibration weight can be stored
in the recess in the cabinet left and rear of the machine.
Routine:
The calibration weight supplied with the machine must
be used together with the clamping adapter. Make sure
that the threaded hole on the adapter is in line with the
red indicator marking on the main shaft.
Remove cone and clamp from the mains haft.
Press ENTER key (12) to select the function menu. Use +/-
key (4/5), (6/7) or (8/9) to select the Function 5.
20
30
15
ON
OFF
empty
Grams
mm
5 / 5
160 mm /14" /4,5"
59

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bm 30-2Bm 40-2Bm 11 quickspanBm 30-2 quickspanBm 40-2 quickspan

Tabla de contenido