Descripciones de parámetros
0-23 Display Line 2 Large
Seleccione una variable para mostrarla en la línea 2.
Option:
[1665]
Analog output 42 [mA]
[1666]
Digital Output
[1667]
Pulse input 29[Hz]
[1668]
Pulse Input 33 [Hz]
[1669]
Pulse Output 27 [Hz]
4
4
[1671]
Relay output
[1672]
Counter A
[1673]
Counter B
[1674]
Prec. Stop Counter
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[1684]
Comm. Option STW
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
[1690]
Alarm Word
[1691]
Alarm Word 2
[1692]
Warning Word
[1693]
Warning Word 2
[1694]
Ext. Status Word
[1695]
Ext. Status Word 2
[1697]
Alarm Word 3
[1890]
Process PID Error
[1891]
Process PID Output
[1892]
Process PID Clamped Output
[1893]
Process PID Gain Scaled Output
[2117]
Ext. 1 Reference [Unit]
[2118]
Ext. 1 Feedback [Unit]
[2119]
Ext. 1 Output [%]
[3401]
PCD 1 Write For Application
[3402]
PCD 2 Write For Application
[3403]
PCD 3 Write For Application
[3404]
PCD 4 Write For Application
[3405]
PCD 5 Write For Application
[3406]
PCD 6 Write For Application
[3407]
PCD 7 Write For Application
[3408]
PCD 8 Write For Application
[3409]
PCD 9 Write For Application
[3410]
PCD 10 Write For Application
[3421]
PCD 1 Read For Application
[3422]
PCD 2 Read For Application
[3423]
PCD 3 Read For Application
[3424]
PCD 4 Read For Application
[3425]
PCD 5 Read For Application
[3426]
PCD 6 Read For Application
[3427]
PCD 7 Read For Application
[3428]
PCD 8 Read For Application
[3429]
PCD 9 Read For Application
[3430]
PCD 10 Read For Application
[3450]
Actual Position
[3456]
Track Error
30
®
VLT
Midi Drive FC 280
Función:
Danfoss A/S © 07/2016 Reservados todos los derechos.
0-24 Display Line 3 Large
Seleccionar una variable que se mostrará en la línea 3.
Option:
[0]
None
[37]
Display Text 1
[38]
Display Text 2
[39]
Display Text 3
[748]
PCD Feed Forward
[953]
Profibus Warning Word
[1005]
Readout Transmit Error Counter
[1006]
Readout Receive Error Counter
[1230]
Warning Parameter
[1501]
Running Hours
[1502]
kWh Counter
*
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference [%]
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1620]
Motor Angle
[1622]
Torque [%]
[1630]
DC Link Voltage
[1633]
Brake Energy /2 min
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1636]
Inv. Nom. Current
[1637]
Inv. Max. Current
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback[Unit]
[1653]
Digi Pot Reference
[1657]
Feedback [RPM]
[1660]
Digital Input
[1661]
Terminal 53 Setting
[1662]
Analog input 53
[1663]
Terminal 54 Setting
[1664]
Analog input 54
[1665]
Analog output 42 [mA]
[1666]
Digital Output
[1667]
Pulse input 29[Hz]
[1668]
Pulse Input 33 [Hz]
[1669]
Pulse Output 27 [Hz]
[1671]
Relay output