English
5.4 Special Chicken Unit
n The special chicken CONVOTHERM has a separate
drain for grease and fat in the unit base. Grease, fat and
water that drips from the chickens are collected in a
special grease collection tray and are directed to the
outside of the unit via a separate grease drain in the base
of the unit. The grease drain must be connected to into an
appropriate, tip-safe grease collection tank (approx. 10-15
liters, on site). Attention: Danger of burns when
working with hot grease!
n Separation trays are inserted between the chicken grids
to avoid water and fat that dropping from the chickens
above washing away the spices.
n When roasting chickens, the unit must be used with an
open grease drain. The open grease drain influences the
humidity control. Therefore the cooking results are also
influenced in programs with steam.
n Upon delivery:
Pos.
Description
1
Separation tray
2
Chicken rack
3
Grease collection tray
4
Elbow
5
Hose with hose
connector
Shorten if necessary or
you can use a longer
hose, too
6
Fastening screw for
grease drain
n Unit on open stand or unit on closed stand in special
Pic. 25
chicken version:
–
Fit the hose connector to the threaded connector of the
grease drain under the unit base.
–
Lead the hose downwards to the grease tank.
–
Fill approx. 5 cm water into the grease tank, so that the
opening of the hose is completely under the surface of the
water (level of water).
Take care that the end of the hose in the grease collection tank is
not blocked!
Art.-Nr.: 7006300 / Ausgabe 06/2003
Part No.
Number per
unit
6.10
10.10
3406581
1
2
3001090
2
3
3406580
1
1
6005144
1
1
7002024
1
1
+
6006108
+
6006087
6006078
1
1
Seite 21 / 71
n Unit on closed stand or table:
–
Disassemble the cover of the condenser.
–
Fit the elbow to the threaded connector of the grease drain
under the unit base.
–
Mount the hose with the hose connector to the elbow.
–
Lead the hose out sidewards to the grease tank.
–
Fill approx. 5 cm water into the grease tank, so that the
opening of the hose is completely under the surface of the
water (level of water).
Take care that the end of the hose in the grease collection tank is
not blocked!
–
Mount the cover of the condenser again.
n Safety advice:
It is not recommended that the unit be used with an
open grease drain when:
–
The connection of the grease drain is not as described in this
installation advice
–
The drain of the grease is to an open container under the unit
–
The grease tank contains an incorrect level of water
Faults that can be traced to improper installation
invalidate any claims against the guarantee.
When flushing the steam generator and when
cleaning the unit with the hand shower, remove the
fat collection tray from the unit and close the fat
drain with the screw. Otherwise, all the water from
the cleaning process will flow into the grease tank.
à Danger of the grease tank overflowing!
n Preparation of the unit for roasting chickens:
–
Open the grease drain •.
–
Insert the grease collection tray ‚ into the unit (do not insert
onto the shelve rack, but directly onto the base of the unit).
Attention: The drain of the grease collection tray must be
positioned in the center of the additional grease drain in the base
of the unit.
–
Insert the separation trays ƒ.
–
After preheating, insert the chicken racks „, which have
been stocked with chicken.
Pic. 26
Pic. 27
Pic. 28