Aventics DDL Serie, CL03 Serie Instrucciones De Servicio página 57

Ocultar thumbs Ver también para DDL Serie, CL03 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 181
During assembly
During commissioning
During operation
During cleaning
AVENTICS | DDL, CL03/CL03-XL | R402003658–BDL–001–AE
W
A 24 V power pack supplies all components with electricity.
The power pack must be fitted with a safe isolation in
accordance with EN 60742, VDE 0551 classification. This
ensures that the electric circuits comply with SELV/PELV
electric circuits in accordance with IEC 60364-4-41.
W
Switch off the operating voltage before connecting or
removing the plugs.
W
The warranty only applies to the delivered configuration.
The warranty will not apply if the product is incorrectly
assembled.
W
Make sure the relevant system component is not under
pressure or voltage before assembly or disassembly.
Ensure that the system is prevented from power restoration
during assembly work.
W
Ground the modules and valve system. Observe the
following standards when installing the system:
– DIN EN 50178, classification VDE 0160
– VDE 0100
W
Installation may only be performed in a voltage-free and
pressure-free state and only by a qualified technician. In
order to avoid accidents caused by dangerous movements
of the actuators, electrical commissioning may only be
carried out in a pressure-free state.
W
Do not put the system into operation before it is completely
assembled as well as correctly wired and configured, and
after it has been tested.
W
The device is subject to the restrictions of the IP 65
protection class. Before commissioning, make sure that all
the connection seals and plugs are leaktight to prevent
fluids and foreign bodies from penetrating the device.
W
Make sure that there is a sufficient exchange of air or
enough cooling if your valve system has any of the following:
– Fully equipped system
– Continuously loaded solenoid valves
W
Never use solvents or strong detergents. Only clean the
device using a slightly damp cloth. Only use water and, if
necessary, a mild detergent.
57