AVENTICS | DDL, CL03/CL03-XL | R402003658–BDL–001–AE
Commissioning and Operation
Automatic addressing
S5
S6
ON
OFF
Table 8:
Selecting the DDL data rate with the S6 switch, bit 1
DDL participants
Pressure regulator
Valve driver
Valve driver
Input module
Output module
1)
Lowest address is not 1 and there is a gap (4).
2)
Address 0 must not be used.
If there is only one participant per type in the DDL link structure,
the bus coupler can set the addresses automatically.
O
Set the S5 rotary switch to position 0 (= address 0) for
automatic addressing.
In this case, the DDL will automatically assign addresses to the
participants.
W
If automatic addressing is used, no addresses may be used
between 1 and 14 (1 to E).
W
Further information on the addressing rules can be found in
the "DDL Drive & Diagnostic Link" system description
R499050030 (German), R499050031 (English).

7.1.3 Setting the output data length for valves

The number of valve outputs can be set with bits 3 and 4 on the
S6 switch. There is an option to optimize the data range needed
in the controller with smaller valve units. This setting only
applies to the valves.
Correct
Incorrect
1
2
2
3
3
5
4
6
5
7
1)
2)
Incorrect
0
1
2
3
4