Setting the menu (cont.)
AUDIO SETTING
Settings for the audio output balance, EMBEDDED AUDIO signals and level meter.
Item
BALANCE
E.AUDIO GROUP *
1
LEVEL METER SETTING *
1
– LEVEL METER ch
– BAR TYPE
– REFERENCE LEVEL
– OVER LEVEL
– BAR BRIGHTNESS
– PEAK HOLD
*
1
Memorized for each input.
16
Content
Adjust the balance between the right and left speakers.
Select the audio channel group of the EMBEDDED AUDIO signals.
The setting values and selectable audio channels of EMBEDDED AUDIO signals are as follows.
1G
:
Channel 1/2/3/4/1+2/3+4/1 – 4 (1G)
2G
:
Channel 5/6/7/8/5+6/7+8/5 – 8 (2G)
1-2G
:
Channel 1/2/3/4/5/6/7/8/1+2/3+4/5+6/7+8/1 – 4 (1G)/5 – 8 (2G)/1 – 8 (1G+2G)
3G
:
Channel 9/10/11/12/9+10/11+12/9 – 12 (3G)
1-3G
:
Channel 1/2/3/4/5/6/7/8/9/10/11/12/1+2/3+4/5+6/7+8/9+10/11+12/1 – 4 (1G)/
5 – 8 (2G)/9 – 12 (3G)/1 – 8 (1G+2G)/1 – 12 (1-3G)
4G
:
Channel 13/14/15/16/13+14/15+16/13 – 16 (4G)
1-4G
:
Channel 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/16/1+2/3+4/5+6/7+8/9+10/11+12
/13+14/15+16/1 – 4 (1G)/5 – 8 (2G)/9 – 12 (3G)/13 – 16 (4G)/1 – 8 (1G+2G)/
1 – 12 (1-3G)/1 – 16 (1-4G)
• G means GROUP
Adjust the level meter display for the EMBEDDED AUDIO signals.
Example of the level meter display —Level meter position and audio channels
Ex.: When "LEVEL METER ch" is set to "LINE" and "BAR TYPE" is set to "3COLORS"
• The level meter with no audio signal input is displayed in white for "3COLORS", and in gray for "W.100."
• You can select the position of the level meter display—top or bottom of the screen (☞ "POSITION" in
"INFORMATION" on page 21).
• When "PEAK HOLD" is set to "ON," the maximum level meter value will remain displayed for a set period of
time.
• The number of audio channels that are displayed on the level meter may vary according to sellection of "E.
AUDIO GROUP".
Select how the audio channels are displayed on the level meter.
LINE
:
Displays the channels 1 – 8 at the left of the screen and 9 – 16 at the right.
DIVIDE
:
Displays the odd channels at the left of the screen and the even channels at
the right.
Select the color of the level meter display.
3COLORS
:
Coloring for each level
W.100
:
White
Select the standard input level indicated on the level meter.
Select the input level's lower limit indicated in red for the "3COLORS" display.
Select the brightness of the level meter.
Activates/deactivates the peak hold function of the level meter.
OVER LEVEL
REFERENCE LEVEL
Red
Yellow
Green
Setting value
L5 – L1, 0, R1 – R5
1G, 2G, 3G, 4G,
1-2G, 1-3G, 1-4G
OFF
LINE
DIVIDE
3COLORS
W.100
−20dB, −18dB
−10dB, −8dB,
−6dB, −4dB, −2dB
LOW, HIGH
OFF, ON