monty 3300 / 3300AIR
Turntable does not hold the rim.
1. Jaws are dirty.
• Clean jaw teeth.
2. Turntable dirty.
• Clean and lubricate turntable.
3. Low air pressure.
• Check air pressure
4. Jaw teeth worn out.
• Check jaws condition.
• Call the authorized service center for assistance
Machine damages rims.
1. Plastic insert in mount/de-mount tool worn out.
• Replace the plastic insert in the mount/demount tool.
2. Plastic protector in jaws worn out.
• Replace plastic protector in jaws.
Column bangs when tilting.
1.
Low air pressure.
Check air pressure.
2.
Tilt cylinder defective.
Call the authorized service center for assistance.