Storage, Transport, Disposal; Technical Specifications - Franklin Electric 6 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Encapsulated Submersible Motors

3 Storage, transport, disposal

3
Storage, transport, disposal
Storage
Transport
DANGER
Unpacking
DANGER
Disposal
4

Technical specifications

Description
Performance/model number
Voltage range
Frequency tolerance
Voltage tolerance
(on the motor terminals)
Speed
Start alternatives
Switching frequency
Protection
Insulation class
4
Store the motor in its original packaging until the time of installing it.
If the motor is stored standing up, make sure that it cannot topple over (shaft always pointing up!).
Do not store the motor in direct sunlight or within the reach of other heat sources.
Observe the storage temperature (–15 - +60 °C, see Technical specifications).
Falling loads may cause lethal injuries or may crush parts of the body!
Nobody is allowed to be located under suspended loads.
Only use approved hoisting gear.
Select the hoisting gear on the basis of the total weight to be transported.
After unpacking the motor check it for possible damage, e.g. damage to the diaphragm cover, housing,
endbell, connection and motor cable.
Immediately inform the supplier of any damage found.
Danger to life due to electrocution if the motor cable is damaged!
Do not install the motor and do not put it into operation.
In order to avoid environmental damage:
Avoid contamination by lubricants, detergents etc.
Dispose of the motor and the packaging material in a proper, environmentally sound manner.
Observe local regulations.
Value
6": 4 - 45 kW (HighTemp90 up to 30 kW)
8": 30 - 150 kW (HighTemp75 up to 110 kW) models 239 ... (279 ...)
220 V ... 690 V, 3~ 50/60/100/120 Hz
± 2%
50 Hz: 10 / +6 % of U
380V –10 % = 342V / 415V + 6 % = 440 V
60/100/120 Hz: +/- 10% of U
approx. 2900 rpm at 50 Hz & 3450 rpm at 60 Hz, 100 Hz approx.. 3000 rpm
Direct starting, wye-delta-starting
6" - Max. 20 switching actions per hour with a minimum off time of 3 min.
8" - Max. 10 switching actions per hour with a minimum off time of 3 min.
IP 68 according to IEC 60529
F (155°C)
models 236 ... (276 ...)
, i.e. at a nominal voltage of 380-415 V:
N
N

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

8 serie6"8"

Tabla de contenido