Franklin Electric 6 Serie Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Description
Submersion depth
Installation location
Operating temperature
Sound pressure level
Maximum axial thrust towards the motor
Maximum axial thrust away from the
motor
(only for a short-time load of max. 3 minutes;
independent of performance rating)
Material
Motor fluid
Weight
Storage temperature
Short motor cable
Connection flange
Temperature monitoring
Medium temperature
Coolant flow speed
(is the speed of the medium flowing along
the motor casing during normal operation)
Value
max. 350 m
Vertical (Mandatory mounting position: vertical, shaft up. Only one diameter step allowed,
i.e. 6" motor on 8" pump). Horizontal (only allowed if the pump size is identical to the
motor size, e.g. 6" motor with 6" pump). The pump has to sufficient "Down Thrust"
transmit to the motor.
No general warranty when built-in in booster systems.
 –3 °C
 70 dB(A)
6" Standard:
4 - 22 kW
30 kW
37 / 45 kW
6" PM:
4 – 22 kW
26 – 45 kW
6" HighTemp90°C: all Ratings
8" Standard and HighTemp75°C:
6":
1400 N
8"
30 - 75 kW 1400 N
93 - 150 kW 3400 N
The person placing the order is responsible for selecting the correct material, specifically as
regards its resistance in the medium to be transported.
WW Version: Stator 304, powder-coated castings
304SS: Stator and castings in 304SS
316SS: Stator and castings in 316SS
FES 91 (approved, water-based emulsion); FES92 (for HighTemp 75/90 motors)
Technical data sheets (see appendix)
15 °C to +60 °C
KTW and VDE- tested (HighTemp Motors with cable without KTW approval)
6":
Motor cable 4.0 m length
8":
Motor cable 8.0 m length
6", 8": NEMA flange (see appendix)
PT100 temperature sensor for retrofitting
SubTemp (Subtrol) temperature sensor + SubMonitor Connect tripping device
PTC temperature sensor (only for 6" 4 - 30 kW, sensor with cable)
6" Standard: 4-30kW Nominal 30°C; 37/45kW Nominal 50°C
6" PM: Nominal 30°C
6" HighTemp90: Nominal 90°C
8" Standard: Nominal 30°C
8" HighTemp75: Nominal 75°C
Nominal 0.16 m/sec
6" PM Motors > 22 kW: 0,5 m/sec
In the event of higher media temperatures operation is only allowed if you
reduce the performance (De-Rating)
increase the coolant flow speed
Encapsulated Submersible Motors
4 Technical specifications
15.5 kN (optional: 45kN)
27.5 kN (optional: 45kN)
45 kN
15.5 kN (optional. 45 kN)
27.5 kN (optional: 45kN)
45kN
45 kN
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

8 serie6"8"