Servicing; Instructions And Warnings For Servicing; Checking Gas Pressure - Angelo Po 0N1FR1GD Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Keep the appliance at peak effi ciency by carrying
out the scheduled servicing procedures recom-
mended by the manufacturer. Proper servicing
will allow the best performance, a longer work-
ing life and constant maintenance of safety re-
quirements.
Important
Before carrying out any servicing procedure,
activate all the safety devices provided and
decide whether staff at work and those in the
vicinity should be informed.
In particular, turn off the gas supply tap, cut
off the electricity supply using the master
switch and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
GB
Undo the screw (B) of the pressure measure-
3)
ment.
Connect the pressure gauge (C) to the pres-
4)
sure test point.
Turn the gas supply tap back on.
5)
Use the knob (D) to light the burner (See para-
6)
graph "switching the appliance on and off " of
the User instructions manual.
Perform a cooking cycle without food at the
7)
maximum temperature then check that the
pressure reading complies with the values pro-
vided in the table at the back of the manual.
Switch off the burner, turn off the gas supply
8)
tap and disconnect the pressure gauge.
Restore the initial conditions after completing
9)
the operation.
3301390_inst_GB_rev.2

SERVICING

INSTRUCTIONS AND WARNINGS FOR SERVICING

CHECKING GAS PRESSURE

Also make sure that during the maintenance
procedure, that the operator is always able
to check whether the plug is disconnected
from the power outlet.
Every 100 working hours have skilled, author-
ised personnel carry out the following opera-
tions:
– A check on the gas pressure and system tight-
ness.
– A check on the effi ciency of the safety thermo-
couple.
– A check on the effi ciency of the fl ues, cleaning
them if necessary.
– Check that the safety thermostat is working
correctly.
– check that the electrical system is in good
working order.
A
- 6 -
C B
D
ENGLISH

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0t1fr1gd0n1fr3gd0t1fr3gd1n1fr2gd1t1fr2gd1n1fr4gd