Filtering Oil; Resetting The Appliance - Angelo Po 0N1FR1GD Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

To carry out this operation, proceed as follows.
Important
Before proceeding, allow the appliance to cool
for 10÷15 min., so that the oil reaches a tem-
perature between 50÷120.
Open the hatch (A).
1)
Fit the extension (B) onto the tap (C).
2)
Place the container (D) and the fi lter (E) both
3)
available as optionals, underneath the exten-
sion (B).
Turn on the tap (C) to empty the well.
4)
Turn off the tap (C) on completion of the
5)
operation.
Close the hatch (A).
6)
Caution - Warning
Do not dump oil in the environment; dispose
of it in accordance with the laws in force in the
country of use.
If the safety thermostat is tripped, the applian-
ce has to be restored to the initial working
GB
conditions as follows.
Allow the oil to cool to 30÷40°C.
1)
Open the hatch (A).
2)
Press the button (B) of the safety thermostat
3)
tripped to restore the gas supply.
Important
To identify the thermostat that has been
tripped, check which burner has cut out and
press the corresponding button.
Close the hatch (A).
4)
3301390_ut_GB_rev.1

FILTERING OIL

RESETTING THE APPLIANCE

- 14 -
A
C
B
A
C
E
D
A
B
ENGLISH