To carry out this operation, proceed as follows.
Importante
Important
Before proceeding, allow the appliance to
cool for 10÷15 min., so that the oil reaches a
temperature between 50÷120°C.
Open the hatch (A).
2)
Fit the extension (B) onto the tap (C).
3)
Place the container (D) and the fi lter (E), both
4)
available as optionals, underneath the exten-
sion (B).
Turn on the tap (C) to empty the well.
5)
Turn off the tap (C) on completion of the
6)
operation.
Close the hatch (A).
7)
Caution - Warning
Do not dump oil in the environment; dispo-
se of it in accordance with the laws in force in
the country of use.
If the safety thermostat is tripped, the applian-
ce has to be restored to the initial working
conditions as follows.
Allow the oil to cool to 30-40°C.
1)
Open the hatch (A).
2)
Press the button (B) of the safety thermostat
3)
tripped to restore the gas supply .
Important
Importante
To identify the thermostat that has been
tripped, check which burner has cut out and
press the corresponding button.
Close the hatch (A).
4)
3269870_ut_GB_rev.2
FILTERING OIL
RESETTING THE APPLIANCE
- 13 -