10
Absorbed power of electric pump
11
Rated current
12
Condenser capacity
13
Protection rating
14
Maximum liquid temperature
15
Maximum ambient temperature
16
Maximum operating pressure
17
Weight
18
Serial number
19
Date of manufacture
Sound pressure level
the sound pressure level is below 70dB
(lpA) on the following models:
WP/Multi EVO-A 3-40, WP/Multi EVO-A 5-40,
WP/Multi EVO-A 3-50, WP/Multi EVO-A 5-50.
maximum head
See annex
Transport and storage
On delivery, check that the electric pump
has not been subject to damage during
transport; in this case notify the retailer
immediately.
Check procedure phases:
•   check the exterior of the packaging;
•   remove all product packaging mate-
rial;
•   inspect the product for possible dam-
aged parts;
•   contact the retailer if any defects are
found.
use the original packaging to return the
product to the retailer in the event of de-
fects; otherwise dispose of all packaging
16 16
materials according to current local stan-
dards.
Handle the product in obser-
vance of current accident pre-
vention standards.
During storage, protect the product from
humidity, dust, heat sources, mechanical
damage and external contaminants in or-
der to conserve the quality of the water
subsequently placed in contact with the
pump.
INSTALLATION
install the autoclave on a flat surface and
secure to prevent movement during start-
up and operation, ensuring that there are
no obstructions to the regular flow of
cooling air delivered by the motor fan.
the pump must be installed in a well-ven-
tilated area, and relative humidity in the
environment must not exceed 50% at
40°C (condensate free).
Ensure that the installation site is suffi-
ciently sized to enable assembly of the
pump on the system and future mainte-
nance operations.
Ensure that the pump installation room
or site is not subject to the risk of flooding
by the leakage of liquids or other events
that may cause submersion of the pump
itself.
Ensure that the ambient temperature
does not exceed the values specified on
the data plate.
to avoid breakdown of the sys-
tem with the risk of physical inju-
ry, use pipelines, connectors and
accessories suited to the maximum oper-
ating pressure values.