Pentair NOCCHI WP/Multi EVO-A Manual De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Refer to the "safety instructions".
•   in normal conditions, the electric
pumps do not require any scheduled
maintenance.
•   With a view to prevention of possible
faults, it is recommended to period-
ically check the pressure delivered
and current absorption. A reduction
in pressure is symptomatic of pump
wear. An increase in current absorp-
tion is symptomatic of abnormal
mechanical friction in the pump.
•   Special maintenance may be required
to clean the pump and replace any
worn parts.
•   if the pump is not used for prolonged
periods (e.g. for an entire season) it
should be drained completely rinsed
with clean water and stored in a dry
location.
At least twice a year, inspect the expansi-
on tank and check the pre-charge pres-
sure, sealing efficiency of the joints and
all areas for visible signs of damage and/
or corrosion. to check the pre-charge
pressure, turn off the pump and drain all
water from the system until the system
water pressure has returned to zero. On
completion of the check, restore the sys-
tem to normal conditions.
QUICk TROUBLE-
SHOOTINg gUIDE
Refer to the "safety instructions".
Water leaks from the air valve of the
expansion tank when checking the gas
pressure
•   the membrane inside the tank is
damaged = replace the internal mem-
brane of the tank or replace the tank
itself
The pump does not work
•   No power supply = turn on the switch
and check that no electrical connec-
tions are loose or defective.
•   Check the mains voltage
•   Fuse blown = check that the cables
and relative connections are not de-
fective and replace the fuse if neces-
sary
•   the single phase motor thermal cut-
out has tripped = this is reset auto-
matically once the motor has cooled
•   Motor overload cutout has tripped
= check that the cables and relative
connections are not defective, check
that the pump is not blocked mechan-
ically, or whether the pump winding is
damaged (replace if necessary)
•   Electrical power line damaged =
replace
•   Pump blocked mechanically = clean
•   Control device faulty = replace pres-
sure switch
The pump stops after a short interval of
operation due to a tripped motor pro-
tection device
•   Excessive current absorption = check
the operating condition of the pump
•   if foreign bodies are present, block-
ing hydraulics = clean the hydraulic
components
•   the single phase motor thermal cut-
out has tripped = this is reset auto-
matically once the motor has cooled;
check installation conditions
ENGLISH
21 21

Publicidad

Tabla de contenido
loading

Tabla de contenido