Planning Information

Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing must
cover the entire cooking surface. Where space is not
restricted, a wider hood can be used to increase capture
area.
For proper performance, the hood must be centered
horizontally above the cooking surface.
Distance From Cooking Surface
The installation height ranges from a minimum height of
30'' (762 mm) to a maximum height of 40'' (1,016 mm);
however, it is necessary to follow the cooking appliance
manufacturer's installation instructions for proper hood
height.
Electrical Location
10¼"
10¼"
10¼"
(260)
(260)
(260)
18"
18"
18"
(457)
(457)
* Hood width should be no less
than the width of the cooking
surface.
* 30" (762) min.
* 30" (762) min.
* 30" (762) min.
40" (1,016) max.
40" (1,016) max.
40" (1,016) max.
to Cooking Surface
to Cooking Surface
to Cooking Surface
* Follow cooking appliance
manufacturer's recommendations
3¼" (83)
E
Cooking
Surface
Figure 3: Typical Hood Installation
NOTICE: The hood could incur some damage from heat if
a THERMADOR PROFESSIONAL
rangetop is operated with multiple burners at high settings
under a hood that is installed at minimum clearances.

Electrical Requirements

The unit requires a 120V AC, 60Hz. 15A branch circuit. The
VTR1330 blower in conjunction with a 27" Pro Hood
requires a 20 amp circuit breaker.
The hood should only be connected to a dedicated circuit
(with ground) that has been installed according to relevant
regulations.
When connected to a GFCI-protected supply,
THERMADOR PROFESSIONAL
use in damp locations that are protected from outside
weather conditions and not subject to saturation with water
and other liquids, but can be subject to moderate degrees
of moisture (such as an outdoor covered patio or lanai
area). Refer to local codes, NEC/CEC, and or the Authority
Having Jurisdiction (AHJ) for additional information.
Check your local building codes for proper method of
installation. In the U.S., if there are no applicable local
codes, this unit should be installed in accordance with the
National Electric Code ANSI/NFPA No. 70, Current Issue.
In Canada, installation must be in accordance with the CAN
1- B149.1 and .2 - Installation Codes for Gas Burning
Appliances and/or local codes.
The appliance must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing a wire that allows the electric current to
escape.
WARNING
The appliance must be grounded.
Electrical Data on the Data Rating Plate:
Data, including the model and serial number, is located on
the product data rating plate inside the appliance, visible
after removal of the filter frame (see Figure 28 on page 17).
®
series range or
®
hoods are suitable for
English 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ph30hsPh36hsPh48hsPh36gsPh42gsPh48gs ... Mostrar todo

Tabla de contenido