Cabinet Installation

The hood can be installed under a cabinet by supporting
the hood from the top.
Note: The cabinet must be structurally joined to the wall
studs to support the weight of this hood.
Figure 17 shows the (4) screw holes labeled "K" used for
mounting the hood to the bottom of the cabinet. Make sure
both knockouts have been removed.
A
23"
23"
23"
(584 mm)
(584 mm)
(584 mm)
L
K
NOTE: This figure depicts tap hole and screw hole
locations only.
Figure 17: Tap Hole and Screw Hole Locations
1. In the base of the cabinet, drill 1/8'' (3 mm) tap holes as
indicated in Dimension A in Figure 17 and in Table 2.
2. Screw in (4) 1" (25 mm) screws (provided with hood)
leaving 1/4'' (6 mm) exposed to hang hood on.
3. If the hood is installed for vertical discharge, refer to
Figure 18 to create clearance holes for passage of the
transition and conduit. Refer to Dimension B in
Figure 18 and Table 2.
4. For horizontal discharge, use Figure 11 on page 10 for
the geometry of the cutout required for clearance of the
transition.
5. Hang hood from screws and tighten securely.
6. From inside of hood, insert screws supplied. Drill
through holes, use 5/8'' (16 mm) screws supplied, (1)
on each side and (4) along the front, into bottom of the
cabinet. See screw holes labeled "L" in Figure 17.
English 12
"
1
9
/
16
"
1
7
/
(40 mm)
16
(179 mm)
(179 mm)
(179 mm)
K
L
L
Plan View of Cabinet Cutout
Cooktop
Wall
Centerline
1
"
1
/
8
(29 mm)
23"
(584 mm)
"
3
3
/
16
(81 mm)
Figure 18: Transition and Conduit Locations
HOOD
Tap Holes
SIZE
A, Figure 17
30'' (762 mm)
29'' (736 mm)
36'' (914 mm)
35'' (889 mm)
42'' (1067 mm)
41'' (1041 mm)
48'' (1219 mm)
47'' (1194 mm)
54'' (1372 mm)
53'' (1346 mm)
Table 2: Centerline Hole Dimensions for Tap and Conduit
B
3
"
2
/
8
(60 mm)
"
7
7
/
8
(200 mm)
" (48 mm)
7
1
/
8
3
"
2
/
8
(60mm)
5/8" (16 mm) DIA
clearance holes for
½" (12.7 mm) conduit
to j-box.
Conduit Holes
B, Figure 18
13'' (330 mm)
16'' (406 mm)
19'' (483 mm)
22'' (559 mm)
25'' (635 mm)
Holes

Publicidad