PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
Concept
Code
F11
Temperature setting point
F12
Temperature difference
F13
Max setting temperature
F14
Min setting temperature
Auto mode temperature
F15
Temperature
difference
F17
ID
F19
Password (Installer)
F20
Password (Manufacturer)
F21
Compressor delay time
F22
Compressor Phase protection
F24
Number of circuits*
F25
Water fiow switch delay time
Compressor
F26
Low limit temperature
The lower limit temperature of
F27
Low speed operation
The upper limit temperature of
F28
Low speed operation
F29
OPERATING MODES ENABLED
F31
Defrost start temperature
F32
Defrost end temperature
F33
Defrost start time
F34
Max defrost time
Defrost
Pipe1(2) fault,Defrost start
F35
temperature
F36
Alarm Delay Time after Defrost
F37
4-way valve mode
Remote Cooling MODE
F38
Remote
control
Remote Heating MODE
F39
Maximum consumption
F40
protection
Voltage
consumption
Alarm delay time due to excessive
F42
consumption
Percentage phase curremt
F44
unbalance
Alarm delay time phase curremt
F45
unbalance
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
Parameter name
Range
F14 – F13
1 – 10
30 – 100
1 – 29
0 – 20
1 – 255
0 – 999
0 – 999
1 – 10
0-100
-20 - 10
-10~30
35~100
0 / 1 / 2 / 3
-10 – 0
5 – 35
1– 120
3 – 20
-10 - 20
0 – 120
0 – 30
5 – 50
0 – 60
Factory
Unit
setting
28
°C
1
°C
40
°C
10
°C
1
°C
8
-
-
5
min
1
0 – 1
Depends on
the model
1-2
2
of the
machine
1
min
0
-10
°C
44
°C
1
-3
°C
15
°C
1
min
10
min
7
°C
3
min
0
0 - 1
0
0 – 1
0
0 – 1
Depends on
the model
2-40
10
of the
machine
3
S
20
%
3
S
ENGLISH
Observations
-
0: Without password (Consult your
-
salesman)
0: Without password (Consult your
-
salesman)
0: no protection
1:have protection
1:1 Compressor
2:2 Compressors
Not enabled select -20
1. Temperature differential ±1°C.
2. Always working at low speed (-
10ºC).
Temperature differential ±1°C
0: Automatic mode (C/H)
1: Heat mode (Heat)
2: Cool mode(Cool)
3: Choose the mode (M)
Ambient Temp.
Defrost according to F33/34.
1: heating 4-way valve has electricity
0: heating 4-way valve has not
electricity
0: Always cooling, and the set point is
not taken into account
1 The set point is taken into account
0: Always heating, and the set point is
not taken into account..
1:The set point is taken into
account
0:not enable
PROHEAT II-35 = 18A
PROHEAT II-45 = 23A
PROHEAT II-60 = 32A
PROHEAT II-90 = 23A
PROHEAT II-120 = 32A
Pag: 22