Astralpool PROHEAT II Serie Manual De Instrucciones página 32

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
Phase unbalance
Power supply connections
wrong
Phase loss
Compressor 1 overcurrent
protection
Compressor 2 overcurrent
protection
The time limit running failure
Signal failure
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
A52
Power failure
A91
Wrong connections or lack of connection
A92
Some phase has no voltage
A93
Compressor overcurrent
A94
Compressor overcurrent
A99
Running time exceed
The cable between the display and the
- -
card is badly connected
ENGLISH
Check electrical connections
Check connections of power input
wire
Check electrical connections
Check the system
Check the system
Check the time limit
Check the continuity of the cable, and
the terminal and the cables are well
connected