PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
Alarm delay time phase protection
F46
failure
F47
Phase failure alarm delay time
If there is a power failure, when
the power is restored, PROHEAT II
F49

Autostart

device is reset in the same
condition.
F50
Water Pump Select
Water pump starts time before
F51
compressor starts
Water pump stops time after
F52
compressor stops
Water pump
F53
Water pump start time
and fan
F54
Water pump run time
F55
Exhaust Temp.protection
F56
Water flow switch
F57
Fan overload
Buzzer alarm sound
F58
duration
Min. Ambient Temp. of starting
F59
the Electrical heater
Over high temperature difference
F60
between water inlet and water
outlet failure
Water inlet Temp sensor
F61
adjustment.
Water outlet Temp sensor
F62
adjustment
Alarm and
1 # Calibration temperature
probe
F63
defrost probe 1
calibration
2 # Calibration temperature
F64
defrost probe 2
F65
Ambient Temp sensor adjustment
Compressor 1 exhaust Temp
F66
sensor adjustment
Compressor 2 exhaust Temp
F67
sensor adjustment
Calibration temperature probe
F68
suction compressor 1
Calibration temperature probe
F69
suction compressor 2
F70
Electronic expansion valve
F71
Refrigerant
Maximum output voltage
F72
(Pressure Sensor)
F73
Max. Sensor pressure
Electronic
F74
Initial valve position cool mode
expansion
F75
Initial valve position heat mode
valve
F76
Overheating setting time
(OPTIONAL)
F77
Fine tuning steps
F78
Middle tuning steps
F79
Coarse tuning steps
F80
Target overheating in heat mode
F81
Objective overheati in cold mode
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
2
0 – 30
2
0 – 30
1
0 – 1
1
0 – 1
3
1 – 10
3
0 -10
60
0 – 99
5
0 – 99
115
90–135
1
0 - 1
1
0 - 1
0
0.1 – 10.0
12
-10 – 20
3
0 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
-20 – 20
0
0 – 1
0
0 – 1
4.5
0.5 – 5.0
4.6
0 – 5
240
100 – 480
240
100 – 480
30
0 – 120
1
0 – 10
3
0 – 10
6
0 – 10
6
3 – 20
10
3 – 25
ENGLISH
S
S
1=Enable
0=Not enable
0: water pump is not enable
1: water pump is enable
Contact Voltage = 220v
min
min
min
Check water temperature
min
°C
Compressor Exhaust Temp.
1:Enable
0:Not enable
1:Enable
0:Not enable
0: No alarm sound
606: Alarm sound is always
on until pressing any key
If electrical heater is available
°C
°C
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
°C
(calíbrate)
Adjust the temperature sensor
ºC
(calíbrate)
Adjust the temperature sensor
ºC
(calíbrate)
-
1:enable, 0:disabled
0:R-410-A
-
1:R-407-C
Maximum pressure sensor output
V
voltage for scaling.
MPa
Max. Sensor pressure for scaling
Steps
Steps
S
Steps
EEV adjust steps
Steps
EEV adjust steps
Steps
EEV adjust steps
ºC
ºC
Pag: 23