PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
Press
to pass through all the periods and exit the menu.
NOTE: If the Schedule Program mode is activated and there are no periods scheduled, the
machine will not start.
5. Setting the machine operating mode
Press
to choose the machine operating mode (Heat, Cool and Automatic, only if
F29=3).
Press
for at least 2 seconds to activate or deactivate the Schedule Programming
mode.
6.
Checking the temperatures (Reading variables)
Press
to display the temperature probe settings and compressor consumption
(3 settings for each phase of the compressor). Use
settings.
The values shown refer to the following nomenclature:
T1
Water inlet
Cool sensor 1
temperature
(Defrost Probe)
.
T7
Aspiration
Ambient
Probe 2
temperature
T13
Low Pressure
High Pressure
circuit 1 (BAR)
circuit 2 (BAR)
LP1
T19
Current Phase
Current phase
1-compressor 2
2-compressor 2
NOTE: The compressor consumption settings vary depending on water and outside
temperature and the settings of phase consumptions does not have to be the same.
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
T2
T3
Compressor 1
discharge
temperature
T8
T9
Water outlet
temperature
T14
T15
Low Pressure
circuit 2 (BAR)
HP2
LP2
T20
T21
Current phase.
3-compressor 2
or
to display the various
T4
T5
Sonda de
Cool sensor 2
Aspiración 1
(Defrost Probe)
T10
T11
Valve steps
Valve steps
circuit 1
circuit 2
T16
T17
Current
Current
phase 1-
phase 2-
compressor 1
compressor 1
ENGLISH
T6
Discharge
probe 2
T12
High Pressure
circuit 1 (BAR)
HP1
T18
Current phase
3-compressor
1
Pag: 38