USER'S MANUAL. PROLINK-4/4C
Measuring signal level fluctuation at a pickup (acquisition over a time period)
1. Define the acquisition time interval Measure interval (1 h for example).
2. Activate a column (a measurement configuration you consider significant).
3. Activate the necessary number of rows to be able to perform the study over
the decided upon period of time, taking into account the previously defined
acquisition interval (e.g. for a 24 hour study with an acquisition interval of 1 h
you will need to activate 24 rows).
4. Finally place the cursor on the activated column and press the rotary selector
[4] until the first active cell blinks.
The report obtained will allow you to guarantee the correct operation of the
installation.
4.9.4.5 Clock
An internal clock permits to record date and hour of data acquisitions.
To modify the time/date access the TV mode functions menu, turn the rotary
selector [4] to the Clock function and press to activate it. The monitor will show a
screen labelled CLOCK displaying the hour, minute, second, day, month and year.
To alter any parameter repeatedly press key
want to modify appears shadowed, then turn the rotary selector [4]. If you want to alter
more parameters repeatedly press key
and exit press the rotary selector [4].
4.9.4.6 Input Video
The Input video function enables Scart connector signals to be controlled. There
are four possibilities:
Scart Auto
Scart In
Scart Out
Scart Off
To select the Scart operation mode, access the TV mode functions menu, turn the
rotary selector [4] to the Input video function and press to activate it. The monitor will
show a screen labelled INPUT VIDEO displaying the four available options (as well as
the Exit option). Turn the rotary selector [4] to the mode you require, then press to
activate it.
06/2005
Premium
[31] again. To validate the changes made
Normal Scart operation
Input video operation mode
Output video operation mode
Scart deactivated
[31] until the parameter you