4.9.4.7 Selecting the Channels Table (Channel set)

The PROLINK-4/4C
standard (four for terrestrial television and fourteen for satellite), for greater adaptability
to the selection requirements of different countries or zones. See the channel-frequency
table in appendix A of the manual.
To modify one channel table, access the TV mode functions menu, turn the rotary
selector [4] to the Channel set function and press to activate it. The monitor will then
show the CHANNEL SET screen. Turn the rotary selector [4] to the desired table and
then press the rotary selector [4] again to activate.

4.9.4.8 Measurement Units

The PROLINK-4/4C
and channel power: dBµV, dBmV and dBm.
To select the units of measurement, access the TV mode functions menu, turn the
rotary selector [4] to select the Units function and press to activate it. The monitor will
show a screen labelled UNITS displaying the three available options (as well as the Exit
option). Turn the rotary selector [4] to the units you require, then press to activate it.

4.9.4.9 Power Off Mode (Manual power)

The PROLINK-4/4C
Automatic (unit disconnects automatically after 15 minutes without operating on any
control).
To select the power-off mode, access the TV mode functions menu, turn the
rotary selector [4] to select the Manual power function and press to activate it. The
monitor will show a screen labelled POWER OFF displaying the two available options
(as well as the Exit option). Turn the rotary selector [4] to select the power-off mode you
require, then press to activate it.

4.9.4.10 C/N setup

To measure C/N the PROLINK-4/4C
mode:
C/N (Auto)
C/N (Reference noise)
Page 80
Premium
comes with eighteen stored channel tables as
Premium
offers three measurement units to measure level
Premium
offers two power-off modes: Manual and
Premium
The PROLINK-4/4C
frequency where noise level is measured, according
with:
f noise = f tuning - ½ Channel BW.
The user defines the frequency where noise level is
measured (by means of the Reference noise function).
This frequency will be used to measure noise level for
all channels.