Product design
3.3

Automatic feed module AVM

1. Display
2. Start button
3. Stop button
4. EMERGENCY STOP button
5. Buttons for the feed force level
6. Light barrier
7. Protective bar
3.3.1

Description of the AVM buttons

Display: If the control unit is connected to the power supply, the display shows the feed force level currently
selected. A point is shown in the bottom right of the display to signal that the light barrier recognizes the reflector.
The AVM can only be started with reflector recognition.
If a fault occurs, this indicator blinks every second and displays F and a number from 1 to 6.
For error messages/trouble-shooting, see chap. 10.5, p. 101.
Feed buttons: By pressing these buttons, it is possible to preset the desired feed force in 10 levels. If the device is
ready for operation, these buttons may be pressed at any time to set the feed force level or to vary it during process-
ing. If one of the buttons remains pressed by the user, the display runs in the direction selected by the user.
START button: The machining process is initiated by pressing this button when the cutter motor is running.
I
After start-up, this button serves no further function. It also has no function during a fault or while the software
version is being displayed.
STOP button: Pressing this button during the machining process stops the feed and the cutter motor. The cutter
0
motor then has to be returned to the starting position. By pressing the zero button the cutter motor can be turned
back more easily. The cutter motor must not be running. As soon as a point lights up in the bottom right of the
display the AVM can be restarted.
calling up the current version of the AVM: The version is displayed when the
pressed simultaneously. The following sequence then flashes: S 2 0 0 H 1 2 3.
The first letter, S stands for software, the next three letters stand for the software version, then there is an H for
hardware and the three numbers that indicate the hardware version.
Then the display returns to the last feed force level that was set.
eMeRGency STOP button
Only press in an emergency. Pressing the EMERGENCY STOP button interrupts the power supply.
Unlock the button to restart.
With error messages the O button can be used to switch off the AVM, the error then no longer appears in the
display.