– Other anomalies (fig. 6)
When one of the red "40÷80°C" leds
start flashing, switch-off the boiler and
then try to ignite again.
After 2 or 3 unsuccessful attempts, do
not try again but call authorised techni-
cal staff.
LOGICA REMOTE CONTROL
When "PLANET AQUAQUICK" is connec-
ted to the "Logica Remote Control" regu-
lat or,
t he
CR/OFF/SUM/WIN/UNBLOCK must be
placed in the position (
); the knobs of
the hot-water service heating potentiome-
ters do not have any effect and all of the
functions will be managed by the regula-
tor (fig. 7).
1
2
3
4
5
6
KEY
1 Display
2 Info button
3 Operating mode button: automatic operation
4 Operating mode button: manual operation
5 Operating mode button: availability
6 Cover with instruction compartment
7 Temperature knob
8 Presence button
If the "Logica Remote Control" breaks
down, the boiler will function by placing
select or
the selector on the (
obviously without consequent control of
the room temperature.
The operating instructions are reported
inside the cover (fig. 8).
Each setting or modification is displayed
(fig. 9).
7
8
Fig. 8
FLASHING RED LED
SPIA ROSSA INTERMITTENTE
o
), position,
KEY
1 Display, time
2 Heating programme
3 Unit (%/C°)
4 Presence button display
5 External temperature
6 Ambient temperature
7 Holiday function
8 Operating mode
9 Line number/day
10 Burner on
11 Heating function
12 Domestic hot water/temperature/domestic
hot water load
Fig. 6
Fig. 7