2. 1 1.4 Wiring diagram
CÓDIGOS REPUESTOS CONECTORES:
J2 cód. 6260971
J3 cód. 6260981A
2. 1 2
LOGICA REMOTE CONTROL
All the boiler's functions can be managed by
a optional digital multifunctional device code
8092204 for the remote of the boiler itself
and for regulating room climatic conditions
with an operational reserve of 12 hours.
The heating circuit is controlled by the room
temperature sensor built-in the equipment
or by the atmospheric conditions, with or
without environmental inflow, if the boiler is
connected to an external sensor.
Characteristics:
– Ergonomic control unit divided according
to function (control levels)).
– Clear division of basic functions:
• operating regime, correction of set
value and presence button are directly
accessible;
• Dif ferent real current values are
accessible through the "info" button;
• other functions can be programmed
after the cover has been opened;
• special service level with protected
access;
– Each setting or modification is displayed
and confirmed.
– Tome setting (special line for changing
BST/CET).
– Heating programme with max. 3 heating
periods per day, individually selectable.
– Copy function for easy transfer of hea-
ting programme to the next or pre-
vious day.
J4 cód. 6260974
J5 cód. 6260973
J6 cód. 6278602
J6
J5
J4
J3
J2
– Holiday programme: the programme is
interrupted for the holiday period and
automatically restarted on returning
home.
– Option to return the heating program to
default values.
– Programming lock (child safety).
Functions:
– Delivery temperature control guided by
the atmospheric conditions, taking into
account the dynamics of the building.
– Delivery temperature control guided by
atmospheric conditions with influence of
ambient temperature.
– Ambient temperature control only.
– Adjustable influence of ambient tempera-
ture shift .
– Switch-on and switch-off optimisation.
– Rapid lowering.
– ECO functions (daily heating limiter, auto-
matic summer/winter switch-over).
– Controllable maximum delivery tempera-
ture limit (specifically for floor plants).
– Limitation of increase in pre-set delivery
temperature.
– Anti-freeze protection for buildings.
– Hourly programming of the tank unit
temperature on two levels: comfort and
reduced.
– Domestic hot water control with nominal
value requirement and enable.
– Connection to room sensor or switching
of operating regime through the telepho-
ne system with external contact or
KEY
EV1 Gas valve coil
EV2 Gas valve coil
EA
Ignition electrode
ER
Sensing electrode
TS
100°C safety stat
PF
Smoke pressure switch
V
Fan
TPA Water pressure transducer
P
Pump
VP
Divertor valve
SE
External sensor (optional)
TA
Room stat
M
Modulator
SM C.H. sensor (blue)
TL
Limit stat
TR
Transformer 230-24V
FL
Flowmeter
SS
D.H.W. sensor (red)
CR
Logica Remote Control (optional)
PTC Thermostatic electrical heater
NOTE: The room stat (TA) must be con-
nected to the terminals 4-5 after having
removed the jumper.
through a window contact.
– Anti-bacterial.
2. 1 2. 1 Installation
The unit must be installed in the main living
room. For installation, follow the assembly
instructions inserted in the package. At this
point, with the selector knob on (
installer can adjust the basic parameters
settings according to the individual needs
(point 2. 1 0.2).
If there is a thermostatic radiator valve
fitted, this must be set to maximum.
2. 1 2.2 Installation settings
The settings for the basic operating para-
meters for individual needs are reported in
the instruction leaflet supplied with the
"Logica Remote Control" and in the section
reserved for the user in this manual.
For further adjustments which can be car-
ried out by the installer, the "Logica Remote
Control" offers a level of service and para-
meterising which can only be accessed
through a special combination of buttons.
To activate this level of service or parame-
terising press buttons
and
5 seconds. This will activate the paramete-
rising level. Then use the same arrow but-
tons to select the individual input lines and
adjust the values with
or
Fig. 19
), the
least
.
91