– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct
action. Contact the nearest Authorised Technical Service Centre.
– The installation of the boiler and any servicing or maintenance job must be carried out by qualified personnel. Under
no circumstances, the devices sealed by the manufacturer can be tampered with.
– It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equipment is
installed.

LIGHTING AND OPERATION

BOILER IGNITION (fig. 1)
Open the gas valve, lower the control panel
cover and activate the boiler by rotating the
selector knob to the summer positio (
The lighting-up of the green led (
will indicate that the apparatus is switched-
on and ready.
– With the rotary switch in the summer
position (
) the boiler will start-up
upon demand for domestic hot water,
and run at full power to reach the selec-
ted temperature. The gas feeding pres-
sure will then automatically vary to ensu-
re that the required temperature is
kept constant.
– With the rotary switch in the winter
position (
) once the boiler has rea-
ched the value set on the heating
potentiometer, it will start to modulate
in automatically in order to supply the
required power output to the system.
The operation of the boiler will be stop-
ped through the intervention of the
timer-thermostat or "Logica Remote
Control".
TEMPERATURES ADJUSTMENT (fig. 2)
– The D.H.W. temperature can be adju-
sted by turning the knob of the D.H.W.
potentiometer (
).
When there is a demand for hot water,
the set temperature is displayed on the
red led scale from 35÷80°C and the yel-
low domestic hot water led lights-up at
the same time (
).
– The C.H. temperature can be adjusted
by turning the knob of the C.H. potentio-
meter (
). The set temperature is indi-
cat ed on t he r ed led scale fr om
35÷80°C and the yellow heating led
lights up at the same time (
re optimal boiler efficiency at all times,
we recommend not to drop below a mini-
mum working temperature of 50°C.
USER INSTRUCTIONS
).
)
). To ensu-
WARNINGS
R
R E M O T E
C O N T R O L
OPEN
APRE
SPIA VERDE
GREEN LED
SPIA ROSSA
RED LED
Fig. 1
SPIA GIALLA
ORANGE LED
Fig. 2