Descargar Imprimir esta página

Mechanical Hazards - Daikin AHT VENTO GREEN MC Serie Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131
2 | Safety
Flammable refrigerants
WARNING
The refrigerant is highly flammable. If
leaks occur, refrigerant can escape and
cause an explosive gas/air mixture.
This can result in fire and explosion with a
subsequent fire risk.
▪ Refrigerant R-290 (propane) is classified in
safety group A3 according to EN 378-1.
The refrigerant used and the filling quantity
can be seen on the rating plate (see
→Rating plate and serial number).
▪ Keep ignition sources away (heat, sparks,
open flames, hot surfaces).
▪ Use a damp cloth or sponge to remove
condensation water and for cleaning. Do
not use dry cloths or sponges to dry the
appliance. (Risk of electrostatic charge
and sparking)
▪ Prior to start-up and restarting, fill the drain
with approx. 2 litres (0.5 gallons) of water
(H2O). Prevents carry-over of refrigerant
into drains.
▪ Do not obstruct the ventilation openings in
the appliance housing. Use only original
accessory parts.
▪ Do not use any mechanical devices or
other means (e.g. ice scrapers) to acceler-
ate the defrosting process.
▪ Do not operate any electrical devices (e.g.
wet vacuum cleaners) inside the cooling
compartment that do not correspond to the
design recommended by the manufacturer.
Appliances with explosion protection mark-
ings (see → Explanation of symbols) are
permitted.
▪ Do not use steam or high-pressure clean-
ers for basic cleaning.
▪ Only install the appliance in well-ventilated
rooms.
▪ Do not install the appliance in cellars or
lowered rooms.
▪ Ducts and wall bushings must be sealed un-
der and behind the unit to protect against fire.
▪ Do not damage the refrigerant circuit.
▪ Do not expose the appliance to tempera-
tures higher than 70°C (158°F) during
transport and storage.
▪ Avoid transmitting pulsations and vibra-
tions to the appliance.
▪ Do not allow external forces to act on the
appliance, e.g. careless handling with a lift
truck or floor cleaning machine.
▪ The operator must not drill into the appli-
ance or carry out any other work on it.
▪ Do not crush or bend pipes.
▪ Only qualified staff may carry out work on
the refrigerant circuit.
▪ Only open the refrigerant circuit and suck
off the refrigerant in well-ventilated rooms
outside store business hours (when cus-
tomers are not present) or outdoors.
▪ Disconnect the appliance prior to all
maintenance, service, or repair work (see
34 / 671
→Shutdown). Secure the appliance
against reconnection.
▪ During the repair a competent person with
knowledge of local conditions must be
available as contact for the qualified staff.
CAUTION
Liquid refrigerant.
Frostbite to skin.
▪ Wear safety goggles and safety gloves.
▪ Protect hands and face from contact with
liquid/leaking refrigerant.
Dispose of devices with flammable refrigerant and in-
sulating foam (thermal insulation polyurethane foam
with pentane) appropriately. Inquire with the responsi-
ble authorities about the safety and statutory disposal
regulations applicable to you.

2.5.3 Mechanical hazards

WARNING
Transport of the appliances with indus-
trial trucks.
Risk of injury to persons in the event of a collision.
▪ Observe transport routes for industrial
trucks.
▪ Secure transported goods.
▪ Only trained personnel may operate indus-
trial trucks.
▪ Note the centre of gravity of the device for
safe lifting of the load with the forklift. Infor-
mation is provided on the front and back of
the device packaging.
Appliance tipping hazard.
Persons may become trapped.
▪ Remove the transport frames only when in
the stable and final installation position.
Use an anti-tilt device.
▪ The device may only be installed and dis-
mantled with an anti-tilt device.
▪ Do not remove the anti-tilt device until there
is no more risk of tilting. Fuse protection is
provided, for example, by a wall or opposite
device for island installation. Anti-tilt device
is supplied as an accessory by the AHT in-
stallation service.
▪ Do not remove the additional device-spe-
cific anti-tilt device after installation (see →
Setup and installation). Observe the sepa-
rate assembly instructions.
▪ If you have any questions, contact the
maintenance service (see →Maintenance
services).
Dispose of packaging material and film.
Suffocation hazard.
▪ Keep packaging material and film away
from children.
▪ Do not allow children to play with packaging
material or film.
AHT Cooling Systems GmbH | en
369779_1_1019

Publicidad

loading

Este manual también es adecuado para:

Aht vento green mc 178Aht vento green mc gd 178Aht vento green mc ec 178Aht vento green mc gd ec 178Aht vento green mc air 178Aht vento green mc air gd 178 ... Mostrar todo