goes off) and will appear on the display a message of troubleshooting. After 40
seconds will appear on the boiler's display na alarm signal (code A15) and the boiler
shuts down. The electric power engine keeps running, fueling the boiler's internal
tank until the sensors detect pellets.
To restart the boiler, you will have to refill the storage unit with pellets (at least
until the level sensor detects pellets) and reset the error (see automatic boiler
instruction manual).
The wood pellet storage unit can be installed on either the left or right side of the
boiler. By default, it is configured to be installed on the right side of the boiler.
For greater ease you should proceed to the assembly and adjustment of the
storage unit before installing the boiler.
Adjusting the height of the boiler
With the boiler placed in its final position, and before starting the installation of the
storage unit, you should level the boiler and put it at the same height of the storage
unit. To do so, you should place the storage unit beside the boiler (left or right) and
adjust the leveling feet of this until it is aligned with the storage unit by the upper
zone, as shown in the following pictures.
43