KEY
1 Tile with articulated joint
2 Lead panel
3 Collar
4
Locking screw
5 Reducing fitting
with washer
In these cases, when assembling, recover
the silicone gasket used on the terminal
adapter (5 fig. 15), which is to be replaced
by the doubler, and insert it into the seat
made in the doubler.
For this type of discharge the sum of the
maximum rectilinear development allowed
for the pipes must not exceed 7,00 mm
H 2 O ("25" version) and 11,00 mm H 2 O
("30" version).
When calculating the lengths of pipe, take
into account the parameters given in the
Table 2.
2.9
FORCED OUTLET
The "25 BF" version can also be installed as
a B
type apparatus by assembling the
22
stub pipe inlet/outlet kit code 8089950.
The kit comes with a sector diaphgram,
instruction sheet and a label with the room
aeration warnings to be attached to the boi-
ler casing.
The sector diaphram must be used accor-
ding to the maximum load loss allowed by
the duct, as indicated in fig. 13/a.
The complete range of fittings required to
carry out the installation is given in fig. 17.
The maximum length of the duct is deter-
mined by the load losses of the single atta-
ched fittings (excluding the inlet/outlet
stub pipe) and should not be greater than
8.00 mm H
O.
2
To calculate the load loss of the individual fit-
tings attached see Table 2.
Fig. 15
KEY
1 Inlet/outlet terminal
2 Sectors diaphragm
3 90° elbow MF with point
code 8077407
4a Extension L. 1000 code 8077303
4b Isolated extension L. 1000
code 8077306
5 Locking junction (n. 5)
code 8092700
KEY
1
Air-smokes flow splitting unit
with take-off points code 8093000
2 a 90° elbow MF code 8077404
2 b Isolated 90° elbow MF code 8077408
3 a Extension L. 1000 code 8077303
3 b Isolated extension L. 1000 code 8077306
4
Int.-est. ring kit code 8091500
5
Intake terminal code 8089500
6
Locking junction (n. 5) code 8092700
7
Doubler fitting code 8091400
8
Tile with articulated joint code 8091300
9
Roof outlet terminal L. 1240 code 8091201
10
45° elbow MF code 8077406
11
Condensation outlet
L. 135 code 8092800
12
Tee condensation outlet code 8093300
6 90° elbow MF code 8077404
7 Extension L. 135 with point
code 8077304
8 45° elbow MF code 8077406
9 Condensation outlet L. 135
code 8092800
10 Tile with articulated joint
code 8091300
11 Roof outlet terminal code 8091201
12 Tee condensation outlet code 8093300
Fig. 16
Fig. 17
111