Installation - Sime Planet 25 OF Manual De Instrucciones

Ocultar thumbs Ver también para Planet 25 OF:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

25 BFT" model
2

INSTALLATION

The boiler must be installed in a fixed loca-
tion and only by specialized and qualified
firms in compliance with all instructions
contained in this manual.
Furthermore, the installation must be in
accordance with current standards and
regulations.
2. 1
VENTILATION OF
BOILER ROOM
The "25 OF - 30 OF" version boilers with
less than 35 kW power can be installed in
domestic environments when simply repla-
cing or in a plant room complying with cur-
rent standards In rooms where open
chamber gas appliances are installed, it is
important that at least as much air at least
as much air can arrive as required by nor-
mal combustion of the gas consumed by
the various appliances.
Consequently, it is necessary to make
106
openings in the walls for the air inlet into
the rooms.
These openings must meet the following
requirements:
– Have a total free section of at least 6
cm
2
for every kW of heat input, with a
minimum of 100 cm
2
.
– They must be located as close as possi-
ble to floor level, not prone to obstruc-
tion and protected by a grid which does
not reduce the effective section required
for the passage of air.
The "25 BFR - 25 BF - 30 BF - 25BFT"
version boilers can instead be installed in
any domestic environment without any
location restrictions or comburent air
requirements.
2. 1 . 1
"BT100" tank unit
Model "25 BFT" may be paired with a sepa-
KEY
1 Control panel
2 Gas valve
3 C.H. sensor (SM)
4 100°C safety stat
5 Water-gas exchanger
6 Combustion chamber
7 Fan
8 Positive pressure take-off
9 Negative pressure take-off
10 Somke pressure switch
11 85°C limit stat
12 Flowmeter
13 Automatic breather
14 Motorised diverter valve
15 Pump
16 Ignition transformer
rate "BT100" tank unit. The tank units may
be installed near the boiler (beneath or
beside it) or in another room.
An optional hydraulic connection kit (code
8091110) is available to facilitate installa-
tion underneath the boiler.
2.2
INSTALLATION PLATE
To mount the installation plate supplied as
an optional extra (kit code 8075407), follow
the instructions written below (fig. 4):
– Fix the connecting sheet to plate (A) and
lower plate (B).
– With the template complete, fix plate (A)
to the wall using the two boiler support
screws.
– Check that plate (B) is perfectly horizon-
tal using a spirit level.
– Connect the bends or connecting val-
ves supplied in the optional kit to the
system pipes.
Fig. 3/b