Kärcher SB MU Manual De Instrucciones página 65

Ocultar thumbs Ver también para SB MU:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 111
Display
Cause
F 300
No connection to electronics A7
F 301
Outputs of the electronics A7 overloaded
F 320
No connection to electronics A8
F 321
Outputs of the electronics A8 overloaded
F 322
Current consumption of pump for micro-emulsion (intensive cleaning
complete) too high
F 323
Current consumption of pump for micro-emulsion (intensive cleaning
complete) too low
F 324
Contactor of pump for micro-emulsion (intensive cleaning complete) is
jammed
F 340
No connection to electronics A9
F 341
Outputs of electronics A9 overloaded
F 342
Power consumption of intensive foam pump too high
F 343
Power consumption of intensive foam pump too low
F 344
Contactor of intensive foam pump jammed
F 400
Warm water no pressure
F 401
Fresh water no pressure
F 402
Permeate no pressure
F 403
4. type of water no pressure
F 404
4. Type of water, temperature over 60 °C or external disturbance
F 405
Frost protection no pressure
F 406
Pressure in the frost protection despite switched off anti-freeze pump.Acknowledge the fault. If the fault recurs, call cus-
F 410
Error F 400 occured 4 times within 24 hours.
F 411
Error F 401 has been active for 300 seconds.
F 412
Error F 402 occured 4 times within 24 hours.
F 413
Error F 403 occured 4 times within 24 hours.
F 414
Error F 405 occured 4 times within 24 hours.
F 420
Fault token changer 1
F 421
Fault token changer 2
F 440
No connection to electronics A31
F 441
Outputs of electronics A31 overloaded
F 800
No connection to the electronics A30
F 801
Outputs of the electronics A30 overloaded.
F 802
Fault in softening plant
F 803
Protective motor switch prepressure pump RO tripped.
Remedy
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Call customer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Call customer service.
Check water supply.
Lower water temperature.
Check upstream water treatment system.
Clean the frost protection sieve.
Check the anti-freeze pump.
tomer service.
Check water supply.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Check token changer.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Check external water softening unit.
Reset motor protection switch; call Customer Ser-
vice if the problem recurs.
28
-
EN
65