4. Description of AQC-D13
D
C
K
B
A
K
G
E
H
I
Fig. 5
AQC-D13 measuring cell
Pos.
Description
A
pH electrode / location for pH electrode
B
Redox electrode / location for redox electrode
Pt100 temperature sensor / location for temperature
C
sensor
D
Water sensor / location for water sensor
E
Connection for sample water inlet
F
Connection for sample water outlet
G
Regulation of sample water quantity
H
Sample water filter
I
Sampling cock
J
Measuring electrode for Cl
Reference electrode for Cl
K
reference electrode
L
Cover
M
Acrylic glass cylinder
8
A
B
L
M
J
F
, ClO
, O
2
2
3
, ClO
, O
/ location for
2
2
3
5. General information
This manual contains all important information for users of the
AQC-D13 and the preassembled systems:
•
technical data
•
instructions for start-up, use and maintenance
•
safety information.
Should you require further information, or should problems occur
which are not handled in sufficient depth in this manual, please
contact Grundfos.
6. Applications
The potentiostatic measuring cell AQC-D13 measures the
concentration of chlorine (Cl
) in the pH-range 4.5 to 8.2, chlorine
2
dioxide (ClO
) or ozone (O
). By means of the suitable
2
3
electrodes, it can also measure the pH value and redox potential
for treatment of swimming-pool water and drinking water.
The preassembled systems measure and control the following
parameters, depending on the measuring amplifier and controller
installed:
•
Preassembled system with Conex DIA-1 measuring amplifier
and controller:
– Measurement: free chlorine (Cl
compensation, chlorine dioxide (ClO
temperature.
– Control: chlorine (Cl
), chlorine dioxide (ClO
2
•
Preassembled system with Conex DIA-2 measuring amplifier
and controller:
– Measurement: free chlorine (Cl
compensation, chlorine dioxide (ClO
temperature.
– Control: chlorine (Cl
), chlorine dioxide (ClO
2
pH.
•
Preassembled system with Conex DIA-2Q measuring amplifier
and controller:
– Measurement: free chlorine (Cl
compensation, chlorine dioxide (ClO
temperature.
– Control: chlorine (Cl
), chlorine dioxide (ClO
2
pH, redox potential.
•
Preassembled system with Conex DIS-D measuring amplifier
and controller:
– Measurement: chlorine (Cl
(O
).
3
– Control: chlorine (Cl
), chlorine dioxide (ClO
2
•
Preassembled system with DIP measuring amplifier and
controller:
– Measurement: chlorine (Cl
(O
), pH, redox potential, temperature.
3
– Control: chlorine (Cl
), chlorine dioxide (ClO
2
pH.
), as an option with pH
2
), ozone (O
), pH,
2
3
), ozone (O
2
3
), as an option with pH
2
), ozone (O
), pH,
2
3
), ozone (O
2
3
), as an option with pH
2
), ozone (O
), pH,
2
3
), ozone (O
2
3
), chlorine dioxide (ClO
), ozone
2
2
), ozone (O
2
3
), chlorine dioxide (ClO
), ozone
2
2
), ozone (O
2
3
).
),
),
).
),