L2
Operation
modes
L3
Motor
speed
L4
Output 1 (MOS)
L5
Output 3 (relay)
Output
L6
traffic light
L7
ING1
Delay
L8
brake deactiva-
tion
Note: "
" represents the factory adjustment
L1
S.S. : Open – stop – close - stop
L2
S.S. : Open -stop - close - open
L3
S.S. : Open – close - open - close
L4
Step-Step 2 (less than 2 sec. generates partial opening).
L5
Apartment block 2 (more than 2 sec. generates Stop)
L6
Apartment block
L7
Hold-to-run
Opening in "semi-automatic mode", closing in "hold-to-run"
L8
mode
L1
Speed 1: 80%
L2
Speed 2: 100%
L3
Speed 3: 140%
L4
Speed 4: 180%
L5
Speed 5: Open 80%, close 50%
L6
Speed 6: Open 100%, close 50%
L7
Speed 7: Open 140%, close 60%
L8
Speed 8: Open 180%, close 60%
L1
Door Open Indicator
L2
It activates if the door is closed
L3
It activates if the door is open
L4
Flashing light
L5
Electric block
L6
Flashing light 24
L7
Suction cup
L8
Maintenance indicator
L1
It activates if the door is closed
L2
It activates if the door is open
L3
Courtesy light
L4
Electric block
L5
Radio channel 1
L6
Radio channel 2
L7
Radio channel 3
L8
Radio channel 4
L1
Red traffic light
L2
Green traffic light
L3
One-way traffic light
L4
Flashing light one-way
L5
Two-way traffic light
L6
Door open indicator
L7
Status
L8
Maintenance indicator
L1
Step Step (normally open contact)
L2
Partial Ap 1 (normally open contact)
L3
ALT (normally closed contact)
L4
Foto (normally closed contact)
L5
Foto1 (normally closed contact)
L6
Foto2 (normally closed contact)
L7
Foto3 (normally closed contact)
L8
Emergency (normally closed contact)
L1
0, 0, 0, 0 instant activation
L2
20, 20, 0, 0
L3
50, 50, 20, 20
L4
100, 100, 50, 50
L5
150, 150, 100, 100
L6
200, 200, 150, 150
L7
250, 250, 200, 200
L8
300, 300, 250, 250
It assigns the operation modes.
Sets the motor speed during normal travel
of the motor with inverter.
Selects the device connected to output 1
piloted at MOS.
Selects the device connected to output 3
piloted at RELAY.
Selects the device connected to the traffic
light output.
Selects the function to be associated to
input ING1
Select the delay time in "ms" for brake
deactivation for:
- opening
- closure
- opening stop
- closure stop