Nice NDCC4001 Instrucciones Y Advertencias Para La Instalación Y El Uso página 7

Ocultar thumbs Ver también para NDCC4001:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
Connection
A: CONTROL UNIT POWER SUPPLY cable
B: MOTOR cable
C: FLASHING LIGHT cable
with aerial
D: BLUEBUS DEVICE cable
E: KEY-OPERATED SELECTOR SWITCH cable
F: Spiral cable for sensitive edge
Note 1 – If the power supply cable exceeds 5 m in length, it is necessary to use a cable with a larger cross-section.
Note 2 – If the Bluebus cable is longer than 10 m and reaches up to a maximum of 15 m, a cable with a larger cross-sectional area is required (2x1mm
The Bluebus cable must be separated from the other cables.
Note 3 – These 2 cables may be replaced by a single cable 4 x 0.5 mm
CAUTION! – The cables used must be suited to the installation environment.
A
3
A
4
TABLE 1 - Technical specifications of electrical cables (fig. 2)
Cable type
4 x 1 mm
2
for the Nice gearmotors, dedicated cables sold as
accessories.
ask the manufacturer of the gearmotor for different
brands
2 x 1 mm
(for flashing light)
2
RG58 shielded cable type (for aerial)
2 x 0.5 mm
2
2 cables 2 x 0.25 mm
Nice Spiral cable available as accessory
.
2
B
2
B
C
Maximum length allowed
5 m (note 1)
3 – 5 – 9 – 11 m
10 m
15 m (note 2)
10 m (note 3)
50 m
).
2
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ndcc4002Ndcc4005Ndcc2301

Tabla de contenido