Connecting To The Power Supply; First Start-Up - Zhermack ARIO 35 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
The equipment itself cannot cause explosions or
fire: the equipment is not prepared and/or
designed to operate in environments with
explosive atmosphere or with the risk of fire.
The working area lighting plant is an important
factor for the safety of persons and the quality of
work. In Italy this subject is governed by a
Ministerial Decree that clearly determines the
average level of prescribed lighting. In other
countries the regulations in force are valid
regarding accident-prevention and hygiene in
EN
the workplace.
6.3
SPACE NECESSARY FOR USE
The choice of the place and space required for installation
is an important factor for the quality of work and safety
and for correct maintenance activities. This area must not
only be spacious enough to allow for optimum equipment
operation - also during cleaning and maintenance phases
- but must also be well lit, aired, not dusty and not
exposed to direct sunlight.
6.3.1 WORKTOP
Fig. I: The ARIO 35 laboratory micromotor is designed
to be operated resting on a rigid surface parallel to the
ground.
To this end, examples of suitable surfaces include
laboratory work units (for use standing up) and modelling
benches (for use sitting down) after verifying their stability.
6.4

CONNECTING TO THE POWER SUPPLY

The connection is made using the power supply cable.
Check:
• that mains power supply voltage and frequency
correspond to those indicated on the identification
plate (an incorrect power supply voltage may damage
the equipment);
• that the power supply mains has a suitable earth
connection.
Do not tamper with the power supply cable and
relative plug. For replacement of the same due to
damage and/or wear, only contact Authorised
After-Sales Centres.
An earth connection is mandatory. If an
extension must be used temporarily, it
must be in compliance with the
standards in force in the country of use.
6.5

FIRST START-UP

After placing the ARIO 35 laboratory micromotor correctly
on the work bench as described in paragraph 6.3.1,
proceed as follows:
Fig. 1: Turn the central ring on the handpiece handle
(12) anticlockwise to open the tool change/replacement
clamp:
24
The reference figures can be found on pages 3, 4, 5 and 6 of this manual.
• the first click, obtained with light pressure, releases the
ring;
• the second click, obtained by rotating the ring more
forcibly, opens the clamp.
Extract the brass pin (11).
Fig. 2: Insert the tool (x) and lock it on the end of
the handpiece handle by turning the central ring
(12) clockwise, making sure you obtain the two clicks
described above (see Fig. 1).
Make sure the tool is positioned perfectly.
Fig. 3: Insert the handpiece connector (16) in the
corresponding connector (5) on the front of the control
unit.
Fig. 4: Insert the pedal connector (17) in the
corresponding connector (8) on the back of the control
unit.
Fig. 5: Connect the plug (10) to the power supply.
Follow the instructions given in paragraph 6.4.
meticulously.
Failure to respect any of the above installation
instructions could result in the machine
malfunctioning and invalidates the guarantee.
6.6
DESIGNATED USES
The ARIO 35 laboratory micromotor is conceived for
milling and/or polishing dental elements.
6.7
NON-DECLARED/PROHIBITED USE
Using the equipment for any purpose not
considered in paragraph regarding "Declared use"
shall be considered improper and thus forbidden.
The improper use of the equipment renders
the warranty null and void and Zhermack Spa
declines all liability for any damage to objects
and injury to operators or third parties.
The main reasons for which the warranty is rendered null
and void are given in paragraph 2.2 and in the "Warranty
Certificate" attached to this Manual.
CHAPTER 7: USING THE MACHINE
7.1
GENERAL WARNINGS
To operate in complete safety, respect the work
phases described below scrupulously.
7.2
SAFETY SYSTEMS
In order to guarantee maximum reliability, Zhermack has
carefully chosen the materials and components used to
construct the machine and the machine has undergone
regular testing before delivery.
The materials are top quality and controlled constantly
during acceptance, storage and use in the workshop to
guarantee an absence of damage, deterioration and/or
malfunction.
ARIO 35

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido