4.4 Chimney and fl ue pipe
The fi replace must only be connected to a chimney and
fl ue pipe approved for solid fuel fi replaces with fl ue gas
temperatures as specifi ed in «2.0 Technical Data».
Several solid fuel stoves can be connected to the same
chimney system if the chimney cross section is adequate.
NB: Look into the applicable rules and regulations to
fi nd out what is permitted. Even a good chimney can
function poorly if it is used incorrectly.
The cross-section of the chimney must be designed to fi t the
fi replace. Use «2.0 Technical Data» to calculate the correct
chimney cross-section.
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fi replace and the hole in the chimney. See fi g. 1 for
minimum dimensions.
Make sure that the fl ue pipe rises all the way up to the
chimney.
With a rear outlet, use a fl ue pipe bend with a sweep hatch
to allow sweeping.
Please note that it is extremely important for connections to
have a degree of fl exibility. This is to prevent any movement
in the installation leading to the formation of cracks.
For recommended chimney draught, see «2.0 Technical
Data». For fl ue pipe dimension see "2.0 Technical Data".
NB: The chimney's diameter must be at least just as big
as the fl ue pipe.
NB! The minimum recommended chimney length is 3.5 m
from the fl ue pipe insert. If the draught is too strong, a fl ue
pipe damper can be installed and used to reduce the draught.
14
Operation under different weather
conditions
The effect of the wind on the chimney may have a signifi cant
impact on how the stove reacts under different gust loads. It
may be necessary to adjust the air supply to achieve good
combustion.
4.5 Fitting a fl ue pipe with a top outlet
The product is supplied from the factory with the smoke outlet
fi tted for the top outlet.
Fig. 19
1. Thread the fl ue pipe (A) through the top plate and place it
in the top smoke outlet.
2. Seal well with a gasket (B).
A